MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
GMV 3xxxEN, 3xxxS / DLV-A3
BAĞLANTI
YILDIZ - ÜÇGEN
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
VAR
H/W
SX/CPU : V1
S/W
SX/CPU : > V1.17
TARİH
12.12.2013
ŞEMA NUMARASI
A3-3600-1-P
DOSYA İSMİ
SX-A3-GMV-YU-GAK-P-V1
SAYFA SAYISI
11
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
WEB
E-Mail
+90.212. 629 11 35
www.mik-el.com
destek@mik-el.com
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
9
G
D
m
P1
P2
UN2
UN
UL
US
C
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
PE
S-CF
PE
UN2
US
PE
1F N1
FL1
B
N
L1
L2
FL3
S-KF
FL2
S1
FK/6A
L3
PE
IL
IN
S-UF
4
S-SL
FUPS/10A
3 N3
S-LP
DB
: Makine dairesindeki elektrik dağıtım panosu
S1
S-KF
S-UF
S-SL
S-LP
:
:
:
:
:
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
HİDROLİK ASANSÖRLERDE KULLANIMI
S4A S4B
S5
S6
S7
S9
S10
S11
S12
S-Kn
S-K1
100
6
AL2
AL1
130
120
113
112
111
110
109
108
107
106
105
104
RB2
VML
S3B
D
S13A S13B S13C
6
100
P1
P2
P1 / 8.1:A
P2 / 8.1:A
C
SB
S27
B
L4-n
S26
L4-1
DB : Makine dairesindeki elektrik dağıtım panosu
Ana kesici şalter
Kabin fazı anahtarı
UPS fazı anahtarı
Kuyu aydınlatma anahtarı
Kuyu prizi ve aydınlatma anahtarı
VMP
E
J1
FSL/nA
S-CF : Ana kesici şalter (Kumanda panosu ile elektrik dağıtım panosu arası mesafe 1 m. 'den fazla ise
kullanılması gerekmektedir.)
M2 : 3 fazlı asenkron motor
UPS : Kesintisiz güç kaynağı
A
i
VMD
SB
: Kuyu dibi
J1
S27
L4-1,...,L4-n
S26
:
:
:
:
4
F
KB-CF2
REVİZYON KUTUSUNA
AL2
VDLV
AL1
UPS 600VA
Θ
M2
4
N
(OUT)
3
L
PE
N PE
(IN)
N3
L
M
3~
VML
VMP
VMD
VCOM
VDLV
UN2
UN
UL
US
UN1
UL
PE
IN
IL
IN
N1
IL
1F
W2
V2
U2
W1
V1
U1
PE
L3
L2
L1
N
E
103
k
99
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
AL2
6
l
e
AL1
130
120
113
112
111
US
UL
UL
UN
UN1
UN2
IN
IN
IL
IL
G
PE
8
7
110
109
99
103
VMP
VML
VMD
UL
UL
US
6
RB2
104
105
106
107
108
5
VCOM
VDLV
4
PE
IL
IL
IN
IN
UN1
UN2
UN
N1
1F
V2
W2
3
U2
W1
V1
U1
PE
L3
2
L2
L1
N
1
Kuyu
Kuyu
Kuyu
Kuyu
prizi
aydınlatma anahtarı
aydınlatma lambaları
alarm butonu
5
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
6
KUMANDA PANOSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
S3B : Makine dairesindeki acil stop butonu
S4A : Kabin tamponu kontağı
S4B : Karşı ağırlık tamponu kontağı
S5
: Alt son kesici kontağı
S6
: Üst son kesici kontağı
S7
: Hız regülatörü kontağı
S9
: Kuyu kapağı kontağı
S10 : Gevşek halat kontağı (1:2 askıda)
S11 : Kuyu dibi acil stop butonu
S12 : Hız regülatörü kasnak gergi kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
S-K1,...,S-Kn : Kat kapısı kontakları
7
A
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
SAYFA
2 / 11
1
2
3
4
FT / 4A (C)
TR1
220VAC
E
5
6
F18/6A (B)
380VA
20VAC
18VAC (80VA)
0
k
0
230VAC (150VA)
5
3
1
B
H1
S3
A
S2 : Panodaki termik
manyetik devre
kesici
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
1
1F
UN
ADN
US
UN1
UN2
UL
UL
IN
IN
IL
IL
L1
L2
L3
N
FP / 2A (C)
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
/ 8.1:E
KBT
4.7:D
14
AC
V11
/ 7.1:D
AC
V10
/ 7.1:D
D
11 / 9.1:E
10A / 8.1:B
LRB
/ 4.1:E
UN / 4.1:D
N / 4.1:E
L3 / 4.1:E
L2 / 4.1:E
L1 / 4.1:E
C
TELEFON
B
A
TR1 : Ana besleme ve yalıtım trafosu
H1 : Pano aydınlatma lambası
S3 : Pano aydınlatma anahtarı
3
TARİH
9AC2
11
100B
I>
DV11
1000V/35A
TLFA
TLFB
TLFC
TLFD
I>
AL1
AL1
AL2
AL2
S2
I>
m
İSTEĞE BAĞLI
2
PE
PE
PE
4
ADP
6
N1
N1
C
i
FDP/ 2A (C)
US
UN
N
L3
L2
L1
F11/1A (B)
0
FLIR / 2A (B)
US
1000 / 6.1:E
9AC1 / 8.1:E
AC
55VAC (130VA)
0
l
e
E
100 / 5.1:E
AC
FV/4A (B)
D
D100
1000V/35A
0
9VAC (20VA)
F9/2A
7
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ BESLEME, AYDINLATMA
VE FAN DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3 / 11
2
3
4
5
6
L3
L2
L1
N
E
D
1
3
5
1
KU2
5.7:C
3
5
KD
2
4
5.2:C
6
2
4
6
5.3:C
1
W2
V2
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
5
2
4
6
i
m
U2
W1
V1
U1
A
3
KS
C
B
1
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
1
P1
P2
2
11
KLIR
14 8.1:D
D2000
AC
E
TP / 8.1:B
N / 8.1:B
A1
KBT
220VAC
A2
AC
1000V/35A
11
14 3.7:D
D
U
S14K300
C
B
A
PMD : Faz koruma ve faz
sırası rölesi
3
TARİH
k
l
e
PMD
810
3.7:C / L3
3.7:C / L2
3.7:C / L1
3.7:C / N
3.7:C / LRB
3.7:C / UN
7
2001
1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
MOTOR BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4 / 11
1
2
3
4
5
6
l
e
E
32
KD
31
31
5.2:C
3.7:E /
KS
32
K11
22
5.3:C
100
D
62
5.3:C
C
C1
680nF/630V
R1
i
62
KS
KD
5.2:C
61
C2
A1
680nF/630V
KD
R2
A2
100R/2W
61
680nF/630V
KS
R3
A2
100R/2W
1
3
5
31
62
2
4
6
32
61
B
A
1
3
5
32
62
2
4
6
31
61
4.3:D
4.3:D
4.3:D
5.4:E
5.2:C
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
21
KU2
31
5.6:C
32
5.7:C
k
5.7:C
680nF/630V
K11
R4
A2
680nF/630V
K12
R5
A2
100R/2W
1
3
5
21
61
72
2
4
6
22
62
71
7.4:C
7.5:C
7.4:C
5.4:E
5.7:C
8.2:C
5.4:C
C6
A1
680nF/630V
K21
R6
A2
100R/2W
2
4
6
22
1
3
5
21
7.4:C
7.5:C
7.4:C
5.4:E
/ 8.1:E
100 / 6.1:E
D
RD / 8.1:C
RS / 8.1:C
R11 / 8.1:D
R21 / 8.1:C
RU2 / 8.1:D
61
C5
A1
KRU
K11
61
C4
A1
K11 :
K12 :
K21 :
KU2 :
3
TARİH
K21
22
E
62
C
A1
KU2
A2
100R/2W
10B
1
3
21
2 7.4:C
4 7.5:C
22 5.4:E
1
3
5
14
32
62
2
4
6
13
31
61
4.2:D
4.2:D
4.2:D
8.2:C
5.5:E
5.4:C
/ 8.1:B
B
A
KD : Üçgen kontaktörü
KS : Yıldız kontaktörü
1
22
5.5:C
62
100R/2W
m
4.2:D
4.3:D
4.3:D
5.3:E
5.3:C
21
KU2
C3
A1
K12
21
5.4:C
7
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (Motor gücüne göre)
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ KONTAKTÖR DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5 / 11
1
2
3
4
5
E
100
1000
5.7:E / 100
3.7:E / 1000
140
120
KRL
RSB
k
RMB
RMA
100
1000
D
i
C
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
KLA
KLB
KLB
KLC
DSB V3
KSB2
KLB
KLA
KLA
l
e
E
100 / 8.1:E
1000 / 8.1:E
140 / 7.1:D
120 / 8.1:D
KRL / 8.1:E
RSB / 8.1:E
RMB / 8.1:E
RMA / 8.1:E
D
C
B
A
3
TARİH
K20
K40
KLC
KMB
7
MLA
MLB
m
B
RMA
RMB
RSB
KRL
SLA
SLB
KMA
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
DSB KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6 / 11
1
2
3
4
5
10 hatlı yassı
kablo
D
3.7:D / V11
6.7:E / 140
3.7:D / V10
i
1
K11
C
5.4:C
2
2
K12
5.5:C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
COM
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
VMD
K3
K4
3A
3C
k
5
3
K11
5.4:C
6
6
K12
1
K21
5.6:C
5.5:C
2
5
VDLV
K11
5.4:C
3
K21
5.6:C
K12
5.5:C
VMP
4
4
7
l
e
SV2
4
HİDROLİK ASANSÖRLERDE KULLANIMI
/ 8.1:A
E
D
VS11 / 8.1:C
140 / 8.1:E
3A / 8.1:D
C
4
3
VML
B
VCOM : Valflerin (-) ucu
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
3
TARİH
1
K2
2A
2C
1A
1C
K1
SV2
SX/RLK V1
4A
4C
E
6
A
5
RLK KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7 / 11
3
4
140
130
120
11
14 4.6:D
5.7:D / R11
5.7:D / RU2
7.7:D / 3A
7.7:D / VS11
5.7:D / R21
K11
71
5.7:D /
RS
5.7:D /
RD
K2
3A
3C
4A
4C
72
5.4:C
C
K1
1A
2A
12C
i
K3
K4
5K
5A
5C
6A
6C
KU2
13
14
5.7:C
K5
K6
7K
7C
m
5.7:B /
10B
10A
120
130
140
10B
120
130
140
10B
X1
X2
Gruptaki
diğer
asansör
sistemine
gider
SV2 SV1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
D
032
031
12
02
1000
GB3
GB2
GB1
GB0
1000
Gösterge
bağlantıları
için lütfen
SX-KAT-V1
şema setine
bakınız.
1X
-X
G
F
E
D
C
B
A
100
C
SV5
SV6
Kullanılmayacak!
KSA sistem için girişler
6 / 9.1:E
140 / 9.1:E
130 / 9.1:E
120 / 9.1:E
500 / 10.1:D
501 / 10.1:D
869 / 10.1:D
870 / 10.1:D
B
Kullanılmayacak!
SV3 SV4
K-DP : Makara dairesindeki deprem kontağı
K-YN : Makara dairesindeki yangın kontağı
816
100
806
Çağrı bağlantıları için lütfen
SX-KAT-V1 şema setine bakınız.
K-DP
K-YN
A
KB-CF1
REVİZYON KUTUSUNA
1
Aşağı yön girişleri
E
501
869
870
KS sistem için girişler
Yukarı yön girişleri
SV2
P1
P2
7.7:E / SV2
2.9:C / P1
2.9:C / P2
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
A
S/W V1.17
l
e
100 / 9.1:E
P1
P2
10A
142
817
818
1000
CANL
CANH
1000
100
100
B
3.7:D /
K7
220
N
k
SX/CPU V1
817
818
1000
CANL
CANH
1000
100
100
4.7:E / TP
4.7:E / N
7
6
140
130
120
500
BOŞ
BOŞ
BOŞ
BOŞ
D
1N4007
BOŞ
BOŞ
BOŞ
BOŞ
A2 24VDC
D1
100
1000
9AC1
9AC2
KLIR
MLA
MLB
IN1
IN2
OUT1
OUT2
A1
301
302
303
304
305
306
202
203
204
205
206
207
120
140
130
120
P100
1000
201
202
203
204
205
206
207
208
209
210
211
212
6.7:E / KRL
6.7:D / RMB
6.7:D / RMA
5.7:E / KRU
7.7:D / 140
6.7:E /
6
100
9AC2
9AC1
1000
RSB
OUT1
KRL
RMB
RMA
KRU
500
501
869
870
KRU
E
5
100
P1
P2
2
806
816
100
1
6.7:E / 100
3.7:E / 9AC2
3.7:E / 9AC1
6.7:E / 1000
6.7:D / RSB
UYARI !
Sistem haberleşmesinin sağlıklı çalışabilmesi için bu terminal
grubunun gösterilen sırada ve birarada olması gerekmektedir.
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
SX/CPU KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8 / 11
1
E
2
3
4
5
103
RB2
108
140
130
120
140
130
120
8.7:E / 140
8.7:E / 130
8.7:D / 120
3.7:D / 11
8.7:E / 100
8.7:E / 6
11
100
6
S3A
6
D
100
99
103
S3B
RB2
104
S4A
S4B
105
S5
C
m
106
S6
107
S7
i
14.2.1.4.c 'ye uygun olarak geri alma
çalışmada köprülenecek kontaklar
B
VAR
YOK (Klemensi köprüleyiniz)
S3A : Panodaki acil stop butonu
S3B : Makine dairesindeki acil stop butonu
A
1
S4A :
S4B :
S5 :
S6 :
S7 :
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
k
108
108
3
TARİH
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
109
S9
S9
S10
Kabin tamponu kontağı
Karşı ağırlık tamponu kontağı
Alt son kesici kontağı
Üst son kesici kontağı
Hız regülatörü kontağı
2
ÇİZİM
107
S11
110
S10
111
S11
112
S12
6
l
e
113
113
120
120
130
130
103 / 10.1:D
RB2 / 10.1:D
108 / 10.1:D
140
D
S-K1
C
B
S-K1,...,S-Kn : Kat kapısı
kontakları
A
S12
: Hız regülatörü kasnak gergi
kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
E
S-Kn
S13A S13B S13C
: Kuyu kapağı kontağı
: Gevşek halat kontağı (1:2
askıda)
: Kuyu dibi acil stop butonu
7
5
GÜVENLİK DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
9 / 11
1
2
3
4
5
6
l
e
E
5
3
1
869
869
i
m
A
869
C
B
2-3
103
108
501
501
108
k
1-3
S29
1-4
2-4
1-3
2-3
S30
500
8.7:D /
2-4
501
S28
1-4
E
D
C
B
RS1
2
RB2
4
103
6
500
500
RB2
870
D
RB2
103
108
501
500
870
9.7:E / RB2
9.7:E / 103
9.7:E / 108
8.7:D / 501
8.7:D / 500
8.7:D / 870
7
A
S28 : Panodaki geri alma anahtarı
S29 : Panodaki aşağı yönde geri alma butonu
S30 : Panodaki yukarı yönde geri alma butonu
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
10 / 11
1
E
D
C
1
1F
3
3N
4
99
100
1000
103
104
105
106
107
108
109
110
111
112
113
120
130
140
500
501
869
6
MLA
MLB
100B
810
2001
2
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
Kabin ve kabin lambası besleme fazı
Bağımsız sigortadan geçen kabin fazı
Kuyu prizi fazı
Kuyu nötrü
Kuyu aydınlatma fazı
Panodaki acil stop buton dönüşü
Gösterge ve kontrol devreleri müştereği (+) ucu
Gösterge ve kontrol devreleri dönüşü (-) ucu
Makine dairesindeki acil stop buton dönüşü
Kabin tamponu kontağı ve karşı ağırlık tamponu kontağı dönüşü
Alt son kesici kontağı dönüşü
Üst son kesici kontağı dönüşü
Hız regülatörü kontağı dönüşü
Kabin paraşüt fren kontağı dönüşü
Kuyu kapağı kontağı dönüşü
Gevşek halat kontağı dönüşü
Kuyu dibi acil stop buton dönüşü
Hız regülatörü kasnak gergi kontağı dönüşü
Yedek
Seri bağlı stop kontakları dönüşü
Kat kapısı kontakları dönüşü
Kabin kapısı kontakları dönüşü
Revizyonda çalışma aşağı yön sinyal girişi
Revizyonda çalışma yukarı yön sinyal girişi
Revizyona alma anahtarından gelen normal çalışma sinyal girişi
Kuyu üst limiti aşıldı sinyal girişi
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Batem kartı beslemesi
Lirpomp bobini (-) ucu
Lirpomp bobini (+) ucu
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(-24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+180VDC)
i
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3600-1-P
DOSYA
SX-A3-GMV-YU-GAK-P-V1
ADN
ADP
AL1, AL2
CANH, CANL
L1, L2, L3
N
N1
P1, P2
PE
RB2
RS1
TLFA, TLFB, TLFC, TLFD
U1, V1, W1
U2, V2, W2
IL
IN
UL
UN1
UN
US
VCOM
VDLV
VML
VMD
VMP
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
(+24VDC)
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Şebeke girişleri
(380VAC)
Nötr
(220VAC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Motor termistör sinyal girişleri
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Revizyon anahtarı üzerindeki güvenlik (stop) devresi kontakları dönüşü
(220VAC)
Telefon hattı bağlantı girişleri
Motor sargı çıkışları
(380VAC)
Motor sargı çıkışları
(380VAC)
UPS giriş fazı
(220VAC)
UPS giriş nötrü
(220VAC)
UPS çıkış fazı
(220VAC)
UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış fazı
(220VAC)
Valflerin (-) ucu
(-48VDC)
(+48VDC)
Güvenlik valfi ( A3'e uygun )
Hızlı valfinin (+) ucu
(+48VDC)
Aşağı yön valfinin (+) ucu
(+48VDC)
Yukarı yön valfinin (+) ucu
(+48VDC)
k
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
11 / 11
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
T. DESTEK
+90.212. 629 00 08 pbx
+90.542. 591 30 80
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
GMV 3xxxEN, 3xxxS / DLV-A3
BAĞLANTI
YILDIZ - ÜÇGEN
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
YOK
H/W
SX/CPU : V1
S/W
SX/CPU : > V1.17
TARİH
12.12.2013
ŞEMA NUMARASI
A3-3605-1-P
DOSYA İSMİ
SX-A3-GMV-YU-P-V1
SAYFA SAYISI
11
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
WEB
E-Mail
+90.212. 629 11 35
www.mik-el.com
destek@mik-el.com
9
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
G
D
m
P1
P2
UN2
UN
UL
US
C
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
PE
S-CF
PE
UN2
US
PE
1F N1
FL1
B
N
L1
L2
FL3
S-KF
FL2
S1
FK/6A
L3
PE
IL
IN
S-UF
4
S-SL
FUPS/10A
3 N3
S-LP
DB
: Makine dairesindeki elektrik dağıtım panosu
S1
S-KF
S-UF
S-SL
S-LP
:
:
:
:
:
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
HİDROLİK ASANSÖRLERDE KULLANIMI
S4A S4B
S5
S6
S7
S9
S10
S11
S12
S-Kn
S-K1
100
6
AL2
AL1
130
120
113
112
111
110
109
108
107
106
105
104
RB2
VML
S3B
D
S13A S13B S13C
6
100
P1
P2
P1 / 8.1:A
P2 / 8.1:A
C
SB
S27
B
L4-n
S26
L4-1
DB : Makine dairesindeki elektrik dağıtım panosu
Ana kesici şalter
Kabin fazı anahtarı
UPS fazı anahtarı
Kuyu aydınlatma anahtarı
Kuyu prizi ve aydınlatma anahtarı
VMP
E
J1
FSL/nA
S-CF : Ana kesici şalter (Kumanda panosu ile elektrik dağıtım panosu arası mesafe 1 m. 'den fazla ise
kullanılması gerekmektedir.)
M2 : 3 fazlı asenkron motor
UPS : Kesintisiz güç kaynağı
A
i
VMD
SB
: Kuyu dibi
J1
S27
L4-1,...,L4-n
S26
:
:
:
:
4
F
KB-CF2
REVİZYON KUTUSUNA
AL2
VDLV
AL1
UPS 600VA
Θ
M2
4
N
(OUT)
3
L
PE
N PE
(IN)
N3
L
M
3~
VML
VMP
VMD
VCOM
VDLV
UN2
UN
UL
US
UN1
UL
PE
IN
IL
IN
N1
IL
1F
W2
V2
U2
W1
V1
U1
PE
L3
L2
L1
N
E
103
k
11
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
AL2
6
l
e
AL1
130
120
113
112
111
US
UL
UL
UN
UN1
UN2
IN
IN
IL
IL
G
PE
8
7
110
109
11
103
VMP
VML
VMD
UL
UL
US
6
RB2
104
105
106
107
108
5
VCOM
VDLV
4
PE
IL
IL
IN
IN
UN1
UN2
UN
N1
1F
V2
W2
3
U2
W1
V1
U1
PE
L3
2
L2
L1
N
1
Kuyu
Kuyu
Kuyu
Kuyu
prizi
aydınlatma anahtarı
aydınlatma lambaları
alarm butonu
5
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
6
KUMANDA PANOSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
S3B : Makine dairesindeki acil stop butonu
S4A : Kabin tamponu kontağı
S4B : Karşı ağırlık tamponu kontağı
S5
: Alt son kesici kontağı
S6
: Üst son kesici kontağı
S7
: Hız regülatörü kontağı
S9
: Kuyu kapağı kontağı
S10 : Gevşek halat kontağı (1:2 askıda)
S11 : Kuyu dibi acil stop butonu
S12 : Hız regülatörü kasnak gergi kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
S-K1,...,S-Kn : Kat kapısı kontakları
7
A
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
SAYFA
2 / 11
1
2
3
4
FT / 4A (C)
TR1
220VAC
E
5
6
F18/6A (B)
380VA
20VAC
18VAC (80VA)
0
k
0
230VAC (150VA)
5
3
1
B
H1
S3
A
S2 : Panodaki termik
manyetik devre
kesici
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
1
1F
UN
ADN
US
UN1
UN2
UL
UL
IN
IN
IL
IL
L1
L2
L3
N
FP / 2A (C)
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
/ 8.1:E
KBT
4.7:D
14
AC
V11
/ 7.1:D
AC
V10
/ 7.1:D
D
11 / 9.1:E
10A / 8.1:B
LRB
/ 4.1:E
UN / 4.1:D
N / 4.1:E
L3 / 4.1:E
L2 / 4.1:E
L1 / 4.1:E
C
TELEFON
B
A
TR1 : Ana besleme ve yalıtım trafosu
H1 : Pano aydınlatma lambası
S3 : Pano aydınlatma anahtarı
3
TARİH
9AC2
11
100B
I>
DV11
1000V/35A
TLFA
TLFB
TLFC
TLFD
I>
AL1
AL1
AL2
AL2
S2
I>
m
İSTEĞE BAĞLI
2
PE
PE
PE
4
ADP
6
N1
N1
C
i
FDP/ 2A (C)
US
UN
N
L3
L2
L1
F11/1A (B)
0
FLIR / 2A (B)
US
1000 / 6.1:E
9AC1 / 8.1:E
AC
55VAC (130VA)
0
l
e
E
100 / 5.1:E
AC
FV/4A (B)
D
D100
1000V/35A
0
9VAC (20VA)
F9/2A
7
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ BESLEME, AYDINLATMA
VE FAN DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3 / 11
2
3
4
5
6
L3
L2
L1
N
E
D
1
3
5
1
KU2
5.7:C
3
5
KD
2
4
5.2:C
6
2
4
6
5.3:C
1
W2
V2
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
5
2
4
6
i
m
U2
W1
V1
U1
A
3
KS
C
B
1
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
1
P1
P2
2
11
KLIR
14 8.1:D
D2000
AC
E
TP / 8.1:B
N / 8.1:B
A1
KBT
220VAC
A2
AC
1000V/35A
11
14 3.7:D
D
U
S14K300
C
B
A
PMD : Faz koruma ve faz
sırası rölesi
3
TARİH
k
l
e
PMD
810
3.7:C / L3
3.7:C / L2
3.7:C / L1
3.7:C / N
3.7:C / LRB
3.7:C / UN
7
2001
1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
MOTOR BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4 / 11
1
2
3
4
5
6
l
e
E
32
KD
31
31
5.2:C
3.7:E /
KS
32
K11
22
5.3:C
100
D
62
5.3:C
C
C1
680nF/630V
R1
i
62
KS
KD
5.2:C
61
C2
A1
680nF/630V
KD
R2
A2
100R/2W
61
680nF/630V
KS
R3
A2
100R/2W
1
3
5
31
62
2
4
6
32
61
B
A
1
3
5
32
62
2
4
6
31
61
4.3:D
4.3:D
4.3:D
5.4:E
5.2:C
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
21
KU2
31
5.6:C
32
5.7:C
k
5.7:C
680nF/630V
K11
R4
A2
680nF/630V
K12
R5
A2
100R/2W
1
3
5
21
61
72
2
4
6
22
62
71
7.4:C
7.5:C
7.4:C
5.4:E
5.7:C
8.2:C
5.4:C
C6
A1
680nF/630V
K21
R6
A2
100R/2W
2
4
6
22
1
3
5
21
7.4:C
7.5:C
7.4:C
5.4:E
/ 8.1:E
100 / 6.1:E
D
RD / 8.1:C
RS / 8.1:C
R11 / 8.1:D
R21 / 8.1:C
RU2 / 8.1:D
61
C5
A1
KRU
K11
61
C4
A1
K11 :
K12 :
K21 :
KU2 :
3
TARİH
K21
22
E
62
C
A1
KU2
A2
100R/2W
10B
1
3
21
2 7.4:C
4 7.5:C
22 5.4:E
1
3
5
14
32
62
2
4
6
13
31
61
4.2:D
4.2:D
4.2:D
8.2:C
5.5:E
5.4:C
/ 8.1:B
B
A
KD : Üçgen kontaktörü
KS : Yıldız kontaktörü
1
22
5.5:C
62
100R/2W
m
4.2:D
4.3:D
4.3:D
5.3:E
5.3:C
21
KU2
C3
A1
K12
21
5.4:C
7
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (Motor gücüne göre)
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ KONTAKTÖR DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5 / 11
1
2
3
4
5
E
100
1000
5.7:E / 100
3.7:E / 1000
140
120
KRL
RSB
k
RMB
RMA
100
1000
D
i
C
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
KLA
KLB
KLB
KLC
DSB V3
KSB2
KLB
KLA
KLA
l
e
E
100 / 8.1:E
1000 / 8.1:E
140 / 7.1:D
120 / 8.1:D
KRL / 8.1:E
RSB / 8.1:E
RMB / 8.1:E
RMA / 8.1:E
D
C
B
A
3
TARİH
K20
K40
KLC
KMB
7
MLA
MLB
m
B
RMA
RMB
RSB
KRL
SLA
SLB
KMA
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
DSB KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6 / 11
1
2
3
4
5
10 hatlı yassı
kablo
D
3.7:D / V11
6.7:E / 140
3.7:D / V10
i
1
K11
C
5.4:C
2
2
K12
5.5:C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
COM
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
VMD
K3
K4
3A
3C
k
5
3
K11
5.4:C
6
6
K12
1
K21
5.6:C
5.5:C
2
5
VDLV
K11
5.4:C
3
K21
5.6:C
K12
5.5:C
VMP
4
4
7
l
e
SV2
4
HİDROLİK ASANSÖRLERDE KULLANIMI
/ 8.1:A
E
D
VS11 / 8.1:C
140 / 8.1:E
3A / 8.1:D
C
4
3
VML
B
VCOM : Valflerin (-) ucu
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
3
TARİH
1
K2
2A
2C
1A
1C
K1
SV2
SX/RLK V1
4A
4C
E
6
A
5
RLK KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7 / 11
3
4
140
130
120
11
14 4.6:D
5.7:D / R11
5.7:D / RU2
7.7:D / 3A
7.7:D / VS11
5.7:D / R21
K11
71
5.7:D /
RS
5.7:D /
RD
K2
3A
3C
4A
4C
72
5.4:C
C
K1
1A
2A
12C
i
K3
K4
5K
5A
5C
6A
6C
KU2
13
14
5.7:C
K5
K6
7K
7C
m
5.7:B /
10B
10A
120
130
140
10B
120
130
140
10B
X1
X2
Gruptaki
diğer
asansör
sistemine
gider
SV2 SV1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
D
032
031
12
02
1000
GB3
GB2
GB1
GB0
1000
Gösterge
bağlantıları
için lütfen
SX-KAT-V1
şema setine
bakınız.
1X
-X
G
F
E
D
C
B
A
100
C
SV5
SV6
Kullanılmayacak!
KSA sistem için girişler
6 / 9.1:E
140 / 9.1:E
130 / 9.1:E
120 / 9.1:E
500 / 10.1:D
501 / 10.1:D
869 / 10.1:D
B
Kullanılmayacak!
SV3 SV4
K-DP : Makara dairesindeki deprem kontağı
K-YN : Makara dairesindeki yangın kontağı
816
100
806
Çağrı bağlantıları için lütfen
SX-KAT-V1 şema setine bakınız.
K-DP
K-YN
A
KB-CF1
REVİZYON KUTUSUNA
1
Aşağı yön girişleri
E
501
869
KS sistem için girişler
Yukarı yön girişleri
SV2
P1
P2
7.7:E / SV2
2.9:C / P1
2.9:C / P2
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
A
S/W V1.17
l
e
100 / 9.1:E
P1
P2
10A
142
817
818
1000
CANL
CANH
1000
100
100
B
3.7:D /
K7
220
N
k
SX/CPU V1
817
818
1000
CANL
CANH
1000
100
100
4.7:E / TP
4.7:E / N
7
6
140
130
120
500
BOŞ
BOŞ
BOŞ
BOŞ
D
1N4007
BOŞ
BOŞ
BOŞ
BOŞ
A2 24VDC
D1
100
1000
9AC1
9AC2
KLIR
MLA
MLB
IN1
IN2
OUT1
OUT2
A1
301
302
303
304
305
306
202
203
204
205
206
207
120
140
130
120
P100
1000
201
202
203
204
205
206
207
208
209
210
211
212
6.7:E / KRL
6.7:D / RMB
6.7:D / RMA
5.7:E / KRU
7.7:D / 140
6.7:E /
6
100
9AC2
9AC1
1000
RSB
OUT1
KRL
RMB
RMA
KRU
500
501
869
870
KRU
E
5
100
P1
P2
2
806
816
100
1
6.7:E / 100
3.7:E / 9AC2
3.7:E / 9AC1
6.7:E / 1000
6.7:D / RSB
UYARI !
Sistem haberleşmesinin sağlıklı çalışabilmesi için bu terminal
grubunun gösterilen sırada ve birarada olması gerekmektedir.
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
SX/CPU KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8 / 11
1
E
2
3
4
5
103
RB2
140
130
120
140
130
120
11
8.7:E / 140
8.7:E / 130
8.7:D / 120
3.7:D / 11
8.7:E / 100
8.7:E / 6
100
6
6
100
11
103
RB2
104
105
106
107
D
S3B
S4A
S4B
S5
C
B
m
VAR
YOK (Klemensi köprüleyiniz)
S3B : Makine dairesindeki acil stop butonu
A
1
S4A :
S4B :
S5 :
S6 :
S7 :
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
S7
i
k
108
108
3
TARİH
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
109
S9
S9
S10
Kabin tamponu kontağı
Karşı ağırlık tamponu kontağı
Alt son kesici kontağı
Üst son kesici kontağı
Hız regülatörü kontağı
2
ÇİZİM
S6
107
S11
110
S10
111
S11
112
S12
6
l
e
113
113
120
120
130
130
103 / 10.1:D
RB2 / 10.1:D
E
140
D
S-Kn
S13A S13B S13C
: Kuyu kapağı kontağı
: Gevşek halat kontağı (1:2
askıda)
: Kuyu dibi acil stop butonu
7
S-K1
C
B
S-K1,...,S-Kn : Kat kapısı
kontakları
A
S12
: Hız regülatörü kasnak gergi
kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
GÜVENLİK DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
9 / 11
1
2
3
4
5
E
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
7
l
e
E
D
C
RB2
B
A
3
TARİH
103
869
m
B
k
501
i
C
500
D
RB2
103
501
500
869
9.7:E / RB2
9.7:E / 103
8.7:D / 501
8.7:D / 500
8.7:D / 869
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
10 / 11
1
E
D
C
1
1F
3
3N
4
11
100
1000
103
104
105
106
107
108
109
110
111
112
113
120
130
140
500
501
869
6
MLA
MLB
100B
810
2001
2
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
Kabin ve kabin lambası besleme fazı
Bağımsız sigortadan geçen kabin fazı
Kuyu prizi fazı
Kuyu nötrü
Kuyu aydınlatma fazı
Kumanda panosundaki trafo fazı
Gösterge ve kontrol devreleri müştereği (+) ucu
Gösterge ve kontrol devreleri dönüşü (-) ucu
Makine dairesindeki acil stop buton dönüşü
Kabin tamponu kontağı ve karşı ağırlık tamponu kontağı dönüşü
Alt son kesici kontağı dönüşü
Üst son kesici kontağı dönüşü
Hız regülatörü kontağı dönüşü
Kabin paraşüt fren kontağı dönüşü
Kuyu kapağı kontağı dönüşü
Gevşek halat kontağı dönüşü
Kuyu dibi acil stop buton dönüşü
Hız regülatörü kasnak gergi kontağı dönüşü
Yedek
Seri bağlı stop kontakları dönüşü
Kat kapısı kontakları dönüşü
Kabin kapısı kontakları dönüşü
Revizyonda çalışma aşağı yön sinyal girişi
Revizyonda çalışma yukarı yön sinyal girişi
Revizyona alma anahtarından gelen normal çalışma sinyal girişi
Kuyu üst limiti aşıldı sinyal girişi
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Batem kartı beslemesi
Lirpomp bobini (-) ucu
Lirpomp bobini (+) ucu
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(-24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+180VDC)
i
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3605-1-P
DOSYA
SX-A3-GMV-YU-P-V1
ADN
ADP
AL1, AL2
CANH, CANL
L1, L2, L3
N
N1
P1, P2
PE
RB2
TLFA, TLFB, TLFC, TLFD
U1, V1, W1
U2, V2, W2
IL
IN
UL
UN1
UN
US
VCOM
VDLV
VML
VMD
VMP
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
(+24VDC)
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Şebeke girişleri
(380VAC)
Nötr
(220VAC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Motor termistör sinyal girişleri
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Telefon hattı bağlantı girişleri
Motor sargı çıkışları
(380VAC)
Motor sargı çıkışları
(380VAC)
UPS giriş fazı
(220VAC)
UPS giriş nötrü
(220VAC)
UPS çıkış fazı
(220VAC)
UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış fazı
(220VAC)
Valflerin (-) ucu
(-48VDC)
(+48VDC)
Güvenlik valfi ( A3'e uygun )
Hızlı valfinin (+) ucu
(+48VDC)
Aşağı yön valfinin (+) ucu
(+48VDC)
Yukarı yön valfinin (+) ucu
(+48VDC)
k
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
YILDIZ - ÜÇGEN
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
11 / 11
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
T. DESTEK
+90.212. 629 00 08 pbx
+90.542. 591 30 80
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
GMV 3xxxEN, 3xxxS / DLV-A3
BAĞLANTI
DOĞRUDAN YOL VERME
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
VAR
H/W
SX/CPU : V1
S/W
SX/CPU : > V1.17
TARİH
12.12.2013
ŞEMA NUMARASI
A3-3610-1-P
DOSYA İSMİ
SX-A3-GMV-DY-GAK-P-V1
SAYFA SAYISI
11
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
WEB
E-Mail
+90.212. 629 11 35
www.mik-el.com
destek@mik-el.com
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
9
G
Θ
M2
D
m
P1
P2
UN2
UN
UL
US
C
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
PE
S-CF
PE
UN2
US
PE
1F N1
FL1
B
N
L1
L2
FL3
S-KF
FL2
S1
FK/6A
L3
PE
IL
IN
S-UF
4
S-SL
FUPS/10A
3 N3
S-LP
DB
: Makine dairesindeki elektrik dağıtım panosu
S1
S-KF
S-UF
S-SL
S-LP
:
:
:
:
:
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
HİDROLİK ASANSÖRLERDE KULLANIMI
S4A S4B
S5
S6
S7
S9
S10
S11
S12
S-Kn
S-K1
100
6
AL2
AL1
130
120
113
112
111
110
109
108
107
106
105
104
RB2
VML
S3B
D
S13A S13B S13C
6
100
P1
P2
P1 / 8.1:A
P2 / 8.1:A
C
SB
S27
B
L4-n
S26
L4-1
DB : Makine dairesindeki elektrik dağıtım panosu
Ana kesici şalter
Kabin fazı anahtarı
UPS fazı anahtarı
Kuyu aydınlatma anahtarı
Kuyu prizi ve aydınlatma anahtarı
VMP
E
J1
FSL/nA
S-CF : Ana kesici şalter (Kumanda panosu ile elektrik dağıtım panosu arası mesafe 1 m. 'den fazla ise
kullanılması gerekmektedir.)
M2 : 3 fazlı asenkron motor
UPS : Kesintisiz güç kaynağı
A
i
VMD
SB
: Kuyu dibi
J1
S27
L4-1,...,L4-n
S26
:
:
:
:
4
F
KB-CF2
REVİZYON KUTUSUNA
AL2
VDLV
AL1
UPS 600VA
M
3~
4
N
(OUT)
3
L
PE
N PE
(IN)
N3
L
VML
VMP
VMD
VCOM
VDLV
UN2
UN
UL
US
UN1
UL
PE
IN
IL
IN
N1
IL
1F
PE
W
V
U
L3
L2
L1
N
E
103
k
99
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
AL2
6
l
e
AL1
130
120
113
112
111
US
UL
UL
UN
UN1
UN2
IN
IN
IL
IL
G
PE
8
7
110
109
99
103
VMP
VML
6
RB2
104
105
106
107
108
5
VMD
UL
UL
US
PE
IL
IL
IN
IN
UN1
UN2
UN
N1
1F
4
VCOM
VDLV
3
PE
W
V
U
L3
2
L2
L1
N
1
Kuyu
Kuyu
Kuyu
Kuyu
prizi
aydınlatma anahtarı
aydınlatma lambaları
alarm butonu
5
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
6
KUMANDA PANOSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
S3B : Makine dairesindeki acil stop butonu
S4A : Kabin tamponu kontağı
S4B : Karşı ağırlık tamponu kontağı
S5
: Alt son kesici kontağı
S6
: Üst son kesici kontağı
S7
: Hız regülatörü kontağı
S9
: Kuyu kapağı kontağı
S10 : Gevşek halat kontağı (1:2 askıda)
S11 : Kuyu dibi acil stop butonu
S12 : Hız regülatörü kasnak gergi kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
S-K1,...,S-Kn : Kat kapısı kontakları
7
A
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
SAYFA
2 / 11
1
2
3
4
FT / 4A (C)
TR1
220VAC
E
5
6
F18/6A (B)
380VA
20VAC
18VAC (80VA)
0
k
0
230VAC (150VA)
5
3
1
B
H1
S3
A
S2 : Panodaki termik
manyetik devre
kesici
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
1
1F
UN
ADN
US
UN1
UN2
UL
UL
IN
IN
IL
IL
L1
L2
L3
N
FP / 2A (C)
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
/ 8.1:E
KBT
4.7:D
14
AC
V11
/ 7.1:D
AC
V10
/ 7.1:D
D
11 / 9.1:E
10A / 8.1:B
LRB
/ 4.1:E
UN / 4.1:D
N / 4.1:E
L3 / 4.1:E
L2 / 4.1:E
L1 / 4.1:E
C
TELEFON
B
A
TR1 : Ana besleme ve yalıtım trafosu
H1 : Pano aydınlatma lambası
S3 : Pano aydınlatma anahtarı
3
TARİH
9AC2
11
100B
I>
DV11
1000V/35A
TLFA
TLFB
TLFC
TLFD
I>
AL1
AL1
AL2
AL2
S2
I>
m
İSTEĞE BAĞLI
2
PE
PE
PE
4
ADP
6
N1
N1
C
i
FDP/ 2A (C)
US
UN
N
L3
L2
L1
F11/1A (B)
0
FLIR / 2A (B)
US
1000 / 6.1:E
9AC1 / 8.1:E
AC
55VAC (130VA)
0
l
e
E
100 / 5.1:E
AC
FV/4A (B)
D
D100
1000V/35A
0
9VAC (20VA)
F9/2A
7
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ BESLEME, AYDINLATMA
VE FAN DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3 / 11
2
3
4
5
6
L3
L2
L1
N
E
1
D
3
5
KU2
5.5:C
2
4
6
1
3
5
2
4
6
KU2-1
5.6:C
i
C
1
W
U
A
V
m
B
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
1
P1
P2
2
11
KLIR
14 8.1:D
D2000
AC
E
TP / 8.1:B
N / 8.1:B
A1
KBT
220VAC
A2
AC
11
1000V/35A
14 3.7:D
D
U
S14K300
C
B
A
PMD : Faz koruma ve faz
sırası rölesi
3
TARİH
k
l
e
PMD
810
3.7:C / L3
3.7:C / L2
3.7:C / L1
3.7:C / N
3.7:C / LRB
3.7:C / UN
7
2001
1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
MOTOR BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4 / 11
1
2
3
4
5
6
l
e
E
K11
22
21
K12
21
5.2:C
3.7:E /
100
D
62
KU2
5.5:C
C
C1
C2
A1
680nF/630V
680nF/630V
K11
R1
61
R2
A2
100R/2W
K12
A2
100R/2W
m
1
3
5
21
62
72
B
A
2
4
6
22
61
71
7.4:C
7.5:C
7.4:C
5.4:E
5.5:C
8.2:C
K11 :
K12 :
K21 :
KU2 :
KU2-1 :
1
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
2
4
6
22
1
3
5
21
7.4:C
7.5:C
7.4:C
5.4:E
22
C3
680nF/630V
R3
100R/2W
21
5.4:C
KU2
31
32
5.5:C
KU2-1
32
31
5.6:C
k
C4
A1
680nF/630V
K21
R4
A2
5.2:C
680nF/630V
KU2
R5
A2
1
3
5
32
62
/ 8.1:E
100 / 6.1:E
D
R11 / 8.1:D
R21 / 8.1:C
RU2 / 8.1:D
61
C5
A1
2 7.4:C
4 7.5:C
22 5.4:E
KRU
62
K11
100R/2W
1
3
21
E
C
A1
KU2-1
A2
100R/2W
10B
2
4
6
31
61
4.2:D
4.3:D
4.3:D
5.4:E
5.3:C
1
3
5
31
2
4
6
32
/ 8.1:B
4.2:D
4.3:D
4.3:D
5.5:E
B
A
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü
Yukarı yön kontaktörü
2
ÇİZİM
i
A1
K21
22
5.3:C
7
3
TARİH
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ KONTAKTÖR DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5 / 11
1
2
3
4
5
E
100
1000
5.7:E / 100
3.7:E / 1000
140
120
KRL
RSB
k
RMB
RMA
100
1000
D
i
C
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
KLA
KLB
KLB
KLC
DSB V3
KSB2
KLB
KLA
KLA
l
e
E
100 / 8.1:E
1000 / 8.1:E
140 / 7.1:D
120 / 8.1:D
KRL / 8.1:E
RSB / 8.1:E
RMB / 8.1:E
RMA / 8.1:E
D
C
B
A
3
TARİH
K20
K40
KLC
KMB
7
MLA
MLB
m
B
RMA
RMB
RSB
KRL
SLA
SLB
KMA
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
DSB KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6 / 11
1
2
3
4
5
10 hatlı yassı
kablo
D
3.7:D / V11
6.7:E / 140
3.7:D / V10
i
1
K11
C
5.2:C
2
2
K12
5.3:C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
COM
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
VMD
K3
K4
3A
3C
k
5
3
K11
5.2:C
6
6
K12
1
K21
5.4:C
5.3:C
2
5
VDLV
K11
5.2:C
3
K21
5.4:C
K12
5.3:C
VMP
4
4
7
l
e
SV2
4
HİDROLİK ASANSÖRLERDE KULLANIMI
/ 8.1:A
E
D
VS11 / 8.1:C
140 / 8.1:E
3A / 8.1:D
C
4
3
VML
B
VCOM : Valflerin (-) ucu
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
3
TARİH
1
K2
2A
2C
1A
1C
K1
SV2
SX/RLK V1
4A
4C
E
6
A
5
RLK KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7 / 11
3
4
140
130
120
11
14 4.6:D
5.7:D / R11
5.7:D / RU2
K1
1A
2A
12C
7.7:D / 3A
7.7:D / VS11
5.7:D / R21
K11
71
K2
3A
3C
4A
4C
72
5.2:C
i
K3
K4
5K
5A
5C
6A
6C
C
K5
K6
7K
7C
m
5.7:B /
10B
10A
120
130
140
10B
120
130
140
10B
X1
X2
Gruptaki
diğer
asansör
sistemine
gider
SV2 SV1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
D
032
031
12
02
1000
GB3
GB2
GB1
GB0
1000
Gösterge
bağlantıları
için lütfen
SX-KAT-V1
şema setine
bakınız.
1X
-X
G
F
E
D
C
B
A
100
C
SV5
SV6
Kullanılmayacak!
KSA sistem için girişler
6 / 9.1:E
140 / 9.1:E
130 / 9.1:E
120 / 9.1:E
500 / 10.1:D
501 / 10.1:D
869 / 10.1:D
870 / 10.1:D
B
Kullanılmayacak!
SV3 SV4
K-DP : Makara dairesindeki deprem kontağı
K-YN : Makara dairesindeki yangın kontağı
816
100
806
Çağrı bağlantıları için lütfen
SX-KAT-V1 şema setine bakınız.
K-DP
K-YN
A
KB-CF1
REVİZYON KUTUSUNA
1
Aşağı yön girişleri
E
501
869
870
KS sistem için girişler
Yukarı yön girişleri
SV2
P1
P2
7.7:E / SV2
2.9:C / P1
2.9:C / P2
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
A
S/W V1.17
l
e
100 / 9.1:E
P1
P2
10A
142
817
818
1000
CANL
CANH
1000
100
100
B
3.7:D /
K7
220
N
k
SX/CPU V1
817
818
1000
CANL
CANH
1000
100
100
4.7:E / TP
4.7:E / N
7
6
140
130
120
500
BOŞ
BOŞ
BOŞ
BOŞ
D
1N4007
BOŞ
BOŞ
BOŞ
BOŞ
A2 24VDC
D1
100
1000
9AC1
9AC2
KLIR
MLA
MLB
IN1
IN2
OUT1
OUT2
A1
301
302
303
304
305
306
202
203
204
205
206
207
120
140
130
120
P100
1000
201
202
203
204
205
206
207
208
209
210
211
212
6.7:E / KRL
6.7:D / RMB
6.7:D / RMA
5.7:E / KRU
7.7:D / 140
6.7:E /
6
100
9AC2
9AC1
1000
RSB
OUT1
KRL
RMB
RMA
KRU
500
501
869
870
KRU
E
5
100
P1
P2
2
806
816
100
1
6.7:E / 100
3.7:E / 9AC2
3.7:E / 9AC1
6.7:E / 1000
6.7:D / RSB
UYARI !
Sistem haberleşmesinin sağlıklı çalışabilmesi için bu terminal
grubunun gösterilen sırada ve birarada olması gerekmektedir.
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
SX/CPU KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8 / 11
1
E
2
3
4
5
103
RB2
108
140
130
120
140
130
120
8.7:E / 140
8.7:E / 130
8.7:D / 120
3.7:D / 11
8.7:E / 100
8.7:E / 6
11
100
6
S3A
6
D
100
99
103
S3B
RB2
104
S4A
S4B
105
S5
C
m
106
S6
107
S7
i
14.2.1.4.c 'ye uygun olarak geri alma
çalışmada köprülenecek kontaklar
B
VAR
YOK (Klemensi köprüleyiniz)
S3A : Panodaki acil stop butonu
S3B : Makine dairesindeki acil stop butonu
A
1
S4A :
S4B :
S5 :
S6 :
S7 :
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
k
108
108
3
TARİH
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
109
S9
S9
S10
Kabin tamponu kontağı
Karşı ağırlık tamponu kontağı
Alt son kesici kontağı
Üst son kesici kontağı
Hız regülatörü kontağı
2
ÇİZİM
107
S11
110
S10
111
S11
112
S12
6
l
e
113
113
120
120
130
130
103 / 10.1:D
RB2 / 10.1:D
108 / 10.1:D
140
D
S-K1
C
B
S-K1,...,S-Kn : Kat kapısı
kontakları
A
S12
: Hız regülatörü kasnak gergi
kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
E
S-Kn
S13A S13B S13C
: Kuyu kapağı kontağı
: Gevşek halat kontağı (1:2
askıda)
: Kuyu dibi acil stop butonu
7
5
GÜVENLİK DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
9 / 11
1
2
3
4
5
6
l
e
E
5
3
1
869
869
i
m
A
869
C
B
2-3
103
108
501
501
108
k
1-3
S29
1-4
2-4
1-3
2-3
S30
500
8.7:D /
2-4
501
S28
1-4
E
D
C
B
RS1
2
RB2
4
103
6
500
500
RB2
870
D
RB2
103
108
501
500
870
9.7:E / RB2
9.7:E / 103
9.7:E / 108
8.7:D / 501
8.7:D / 500
8.7:D / 870
7
A
S28 : Panodaki geri alma anahtarı
S29 : Panodaki aşağı yönde geri alma butonu
S30 : Panodaki yukarı yönde geri alma butonu
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
10 / 11
1
E
D
C
1
1F
3
3N
4
99
100
1000
103
104
105
106
107
108
109
110
111
112
113
120
130
140
500
501
869
6
MLA
MLB
100B
810
2001
2
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
Kabin ve kabin lambası besleme fazı
Bağımsız sigortadan geçen kabin fazı
Kuyu prizi fazı
Kuyu nötrü
Kuyu aydınlatma fazı
Panodaki acil stop buton dönüşü
Gösterge ve kontrol devreleri müştereği (+) ucu
Gösterge ve kontrol devreleri dönüşü (-) ucu
Makine dairesindeki acil stop buton dönüşü
Kabin tamponu kontağı ve karşı ağırlık tamponu kontağı dönüşü
Alt son kesici kontağı dönüşü
Üst son kesici kontağı dönüşü
Hız regülatörü kontağı dönüşü
Kabin paraşüt fren kontağı dönüşü
Kuyu kapağı kontağı dönüşü
Gevşek halat kontağı dönüşü
Kuyu dibi acil stop buton dönüşü
Hız regülatörü kasnak gergi kontağı dönüşü
Yedek
Seri bağlı stop kontakları dönüşü
Kat kapısı kontakları dönüşü
Kabin kapısı kontakları dönüşü
Revizyonda çalışma aşağı yön sinyal girişi
Revizyonda çalışma yukarı yön sinyal girişi
Revizyona alma anahtarından gelen normal çalışma sinyal girişi
Kuyu üst limiti aşıldı sinyal girişi
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Batem kartı beslemesi
Lirpomp bobini (-) ucu
Lirpomp bobini (+) ucu
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(-24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+180VDC)
i
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3610-1-P
DOSYA
SX-A3-GMV-DY-GAK-P-V1
ADN
ADP
AL1, AL2
CANH, CANL
L1, L2, L3
N
N1
P1, P2
PE
RB2
RS1
TLFA, TLFB, TLFC, TLFD
U, V, W
IL
IN
UL
UN1
UN
US
VCOM
VDLV
VML
VMD
VMP
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
(+24VDC)
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Şebeke girişleri
(380VAC)
Nötr
(220VAC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Motor termistör sinyal girişleri
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Revizyon anahtarı üzerindeki güvenlik (stop) devresi kontakları dönüşü
(220VAC)
Telefon hattı bağlantı girişleri
(380VAC)
Motor sargı çıkışları
UPS giriş fazı
(220VAC)
UPS giriş nötrü
(220VAC)
UPS çıkış fazı
(220VAC)
UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış fazı
(220VAC)
Valflerin (-) ucu
(-48VDC)
(+48VDC)
Güvenlik valfi ( A3'e uygun )
Hızlı valfinin (+) ucu
(+48VDC)
Aşağı yön valfinin (+) ucu
(+48VDC)
Yukarı yön valfinin (+) ucu
(+48VDC)
k
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
11 / 11
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
T. DESTEK
+90.212. 629 00 08 pbx
+90.542. 591 30 80
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
GMV 3xxxEN, 3xxxS / DLV-A3
BAĞLANTI
DOĞRUDAN YOL VERME
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
YOK
H/W
SX/CPU : V1
S/W
SX/CPU : > V1.17
TARİH
12.12.2013
ŞEMA NUMARASI
A3-3615-1-P
DOSYA İSMİ
SX-A3-GMV-DY-P-V1
SAYFA SAYISI
11
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
WEB
E-Mail
+90.212. 629 11 35
www.mik-el.com
destek@mik-el.com
9
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
G
Θ
M2
D
m
P1
P2
UN2
UN
UL
US
C
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
PE
S-CF
PE
UN2
US
PE
1F N1
FL1
B
N
L1
L2
FL3
S-KF
FL2
S1
FK/6A
L3
PE
IL
IN
S-UF
4
S-SL
FUPS/10A
3 N3
S-LP
DB
: Makine dairesindeki elektrik dağıtım panosu
S1
S-KF
S-UF
S-SL
S-LP
:
:
:
:
:
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
HİDROLİK ASANSÖRLERDE KULLANIMI
S4A S4B
S5
S6
S7
S9
S10
S11
S12
S-Kn
S-K1
100
6
AL2
AL1
130
120
113
112
111
110
109
108
107
106
105
104
RB2
VML
S3B
D
S13A S13B S13C
6
100
P1
P2
P1 / 8.1:A
P2 / 8.1:A
C
SB
S27
B
L4-n
S26
L4-1
DB : Makine dairesindeki elektrik dağıtım panosu
Ana kesici şalter
Kabin fazı anahtarı
UPS fazı anahtarı
Kuyu aydınlatma anahtarı
Kuyu prizi ve aydınlatma anahtarı
VMP
E
J1
FSL/nA
S-CF : Ana kesici şalter (Kumanda panosu ile elektrik dağıtım panosu arası mesafe 1 m. 'den fazla ise
kullanılması gerekmektedir.)
M2 : 3 fazlı asenkron motor
UPS : Kesintisiz güç kaynağı
A
i
VMD
SB
: Kuyu dibi
J1
S27
L4-1,...,L4-n
S26
:
:
:
:
4
F
KB-CF2
REVİZYON KUTUSUNA
AL2
VDLV
AL1
UPS 600VA
M
3~
4
N
(OUT)
3
L
PE
N PE
(IN)
N3
L
VML
VMP
VMD
VCOM
VDLV
UN2
UN
UL
US
UN1
UL
PE
IN
IL
IN
N1
IL
1F
PE
W
V
U
L3
L2
L1
N
E
103
k
11
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
AL2
6
l
e
AL1
130
120
113
112
111
US
UL
UL
UN
UN1
UN2
IN
IN
IL
IL
G
PE
8
7
110
109
11
103
VMP
VML
6
RB2
104
105
106
107
108
5
VMD
UL
UL
US
PE
IL
IL
IN
IN
UN1
UN2
UN
N1
1F
4
VCOM
VDLV
3
PE
W
V
U
L3
2
L2
L1
N
1
Kuyu
Kuyu
Kuyu
Kuyu
prizi
aydınlatma anahtarı
aydınlatma lambaları
alarm butonu
5
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
6
KUMANDA PANOSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
S3B : Makine dairesindeki acil stop butonu
S4A : Kabin tamponu kontağı
S4B : Karşı ağırlık tamponu kontağı
S5
: Alt son kesici kontağı
S6
: Üst son kesici kontağı
S7
: Hız regülatörü kontağı
S9
: Kuyu kapağı kontağı
S10 : Gevşek halat kontağı (1:2 askıda)
S11 : Kuyu dibi acil stop butonu
S12 : Hız regülatörü kasnak gergi kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
S-K1,...,S-Kn : Kat kapısı kontakları
7
A
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
SAYFA
2 / 11
1
2
3
4
FT / 4A (C)
TR1
220VAC
E
5
6
F18/6A (B)
380VA
20VAC
18VAC (80VA)
0
k
0
230VAC (150VA)
5
3
1
B
H1
S3
A
S2 : Panodaki termik
manyetik devre
kesici
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
1
1F
UN
ADN
US
UN1
UN2
UL
UL
IN
IN
IL
IL
L1
L2
L3
N
FP / 2A (C)
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
/ 8.1:E
KBT
4.7:D
14
AC
V11
/ 7.1:D
AC
V10
/ 7.1:D
D
11 / 9.1:E
10A / 8.1:B
LRB
/ 4.1:E
UN / 4.1:D
N / 4.1:E
L3 / 4.1:E
L2 / 4.1:E
L1 / 4.1:E
C
TELEFON
B
A
TR1 : Ana besleme ve yalıtım trafosu
H1 : Pano aydınlatma lambası
S3 : Pano aydınlatma anahtarı
3
TARİH
9AC2
11
100B
I>
DV11
1000V/35A
TLFA
TLFB
TLFC
TLFD
I>
AL1
AL1
AL2
AL2
S2
I>
m
İSTEĞE BAĞLI
2
PE
PE
PE
4
ADP
6
N1
N1
C
i
FDP/ 2A (C)
US
UN
N
L3
L2
L1
F11/1A (B)
0
FLIR / 2A (B)
US
1000 / 6.1:E
9AC1 / 8.1:E
AC
55VAC (130VA)
0
l
e
E
100 / 5.1:E
AC
FV/4A (B)
D
D100
1000V/35A
0
9VAC (20VA)
F9/2A
7
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ BESLEME, AYDINLATMA
VE FAN DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3 / 11
2
3
4
5
6
L3
L2
L1
N
E
1
D
3
5
KU2
5.5:C
2
4
6
1
3
5
2
4
6
KU2-1
5.6:C
i
C
1
W
U
A
V
m
B
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
1
P1
P2
2
11
KLIR
14 8.1:D
D2000
AC
E
TP / 8.1:B
N / 8.1:B
A1
KBT
220VAC
A2
AC
11
1000V/35A
14 3.7:D
D
U
S14K300
C
B
A
PMD : Faz koruma ve faz
sırası rölesi
3
TARİH
k
l
e
PMD
810
3.7:C / L3
3.7:C / L2
3.7:C / L1
3.7:C / N
3.7:C / LRB
3.7:C / UN
7
2001
1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
MOTOR BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4 / 11
1
2
3
4
5
6
l
e
E
K11
22
21
K12
21
5.2:C
3.7:E /
100
D
62
KU2
5.5:C
C
C1
C2
A1
680nF/630V
680nF/630V
K11
R1
61
R2
A2
100R/2W
K12
A2
100R/2W
m
1
3
5
21
62
72
B
A
2
4
6
22
61
71
7.4:C
7.5:C
7.4:C
5.4:E
5.5:C
8.2:C
K11 :
K12 :
K21 :
KU2 :
KU2-1 :
1
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
2
4
6
22
1
3
5
21
7.4:C
7.5:C
7.4:C
5.4:E
22
C3
680nF/630V
R3
100R/2W
21
5.4:C
KU2
31
32
5.5:C
KU2-1
32
31
5.6:C
k
C4
A1
680nF/630V
K21
R4
A2
5.2:C
680nF/630V
KU2
R5
A2
1
3
5
32
62
/ 8.1:E
100 / 6.1:E
D
R11 / 8.1:D
R21 / 8.1:C
RU2 / 8.1:D
61
C5
A1
2 7.4:C
4 7.5:C
22 5.4:E
KRU
62
K11
100R/2W
1
3
21
E
C
A1
KU2-1
A2
100R/2W
10B
2
4
6
31
61
4.2:D
4.3:D
4.3:D
5.4:E
5.3:C
1
3
5
31
2
4
6
32
/ 8.1:B
4.2:D
4.3:D
4.3:D
5.5:E
B
A
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü
Yukarı yön kontaktörü
2
ÇİZİM
i
A1
K21
22
5.3:C
7
3
TARİH
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ KONTAKTÖR DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5 / 11
1
2
3
4
5
E
100
1000
5.7:E / 100
3.7:E / 1000
140
120
KRL
RSB
k
RMB
RMA
100
1000
D
i
C
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
KLA
KLB
KLB
KLC
DSB V3
KSB2
KLB
KLA
KLA
l
e
E
100 / 8.1:E
1000 / 8.1:E
140 / 7.1:D
120 / 8.1:D
KRL / 8.1:E
RSB / 8.1:E
RMB / 8.1:E
RMA / 8.1:E
D
C
B
A
3
TARİH
K20
K40
KLC
KMB
7
MLA
MLB
m
B
RMA
RMB
RSB
KRL
SLA
SLB
KMA
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
DSB KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6 / 11
1
2
3
4
5
10 hatlı yassı
kablo
D
3.7:D / V11
6.7:E / 140
3.7:D / V10
i
1
K11
C
5.2:C
2
2
K12
5.3:C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
COM
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
VMD
K3
K4
3A
3C
k
5
3
K11
5.2:C
6
6
K12
1
K21
5.4:C
5.3:C
2
5
VDLV
K11
5.2:C
3
K21
5.4:C
K12
5.3:C
VMP
4
4
7
l
e
SV2
4
HİDROLİK ASANSÖRLERDE KULLANIMI
/ 8.1:A
E
D
VS11 / 8.1:C
140 / 8.1:E
3A / 8.1:D
C
4
3
VML
B
VCOM : Valflerin (-) ucu
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
3
TARİH
1
K2
2A
2C
1A
1C
K1
SV2
SX/RLK V1
4A
4C
E
6
A
5
RLK KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7 / 11
3
4
140
130
120
11
14 4.6:D
5.7:D / R11
5.7:D / RU2
K1
1A
2A
12C
7.7:D / 3A
7.7:D / VS11
5.7:D / R21
K11
71
K2
3A
3C
4A
4C
72
5.2:C
i
K3
K4
5K
5A
5C
6A
6C
C
K5
K6
7K
7C
m
5.7:B /
10B
10A
120
130
140
10B
120
130
140
10B
X1
X2
Gruptaki
diğer
asansör
sistemine
gider
SV2 SV1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
D
032
031
12
02
1000
GB3
GB2
GB1
GB0
1000
Gösterge
bağlantıları
için lütfen
SX-KAT-V1
şema setine
bakınız.
1X
-X
G
F
E
D
C
B
A
100
C
SV5
SV6
Kullanılmayacak!
KSA sistem için girişler
6 / 9.1:E
140 / 9.1:E
130 / 9.1:E
120 / 9.1:E
500 / 10.1:D
501 / 10.1:D
869 / 10.1:D
B
Kullanılmayacak!
SV3 SV4
K-DP : Makara dairesindeki deprem kontağı
K-YN : Makara dairesindeki yangın kontağı
816
100
806
Çağrı bağlantıları için lütfen
SX-KAT-V1 şema setine bakınız.
K-DP
K-YN
A
KB-CF1
REVİZYON KUTUSUNA
1
Aşağı yön girişleri
E
501
869
KS sistem için girişler
Yukarı yön girişleri
SV2
P1
P2
7.7:E / SV2
2.9:C / P1
2.9:C / P2
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
A
S/W V1.17
l
e
100 / 9.1:E
P1
P2
10A
142
817
818
1000
CANL
CANH
1000
100
100
B
3.7:D /
K7
220
N
k
SX/CPU V1
817
818
1000
CANL
CANH
1000
100
100
4.7:E / TP
4.7:E / N
7
6
140
130
120
500
BOŞ
BOŞ
BOŞ
BOŞ
D
1N4007
BOŞ
BOŞ
BOŞ
BOŞ
A2 24VDC
D1
100
1000
9AC1
9AC2
KLIR
MLA
MLB
IN1
IN2
OUT1
OUT2
A1
301
302
303
304
305
306
202
203
204
205
206
207
120
140
130
120
P100
1000
201
202
203
204
205
206
207
208
209
210
211
212
6.7:E / KRL
6.7:D / RMB
6.7:D / RMA
5.7:E / KRU
7.7:D / 140
6.7:E /
6
100
9AC2
9AC1
1000
RSB
OUT1
KRL
RMB
RMA
KRU
500
501
869
870
KRU
E
5
100
P1
P2
2
806
816
100
1
6.7:E / 100
3.7:E / 9AC2
3.7:E / 9AC1
6.7:E / 1000
6.7:D / RSB
UYARI !
Sistem haberleşmesinin sağlıklı çalışabilmesi için bu terminal
grubunun gösterilen sırada ve birarada olması gerekmektedir.
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
SX/CPU KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8 / 11
1
E
2
3
4
5
103
RB2
140
130
120
140
130
120
11
8.7:E / 140
8.7:E / 130
8.7:D / 120
3.7:D / 11
8.7:E / 100
8.7:E / 6
100
6
6
100
11
103
RB2
104
105
106
107
D
S3B
S4A
S4B
S5
C
B
m
VAR
YOK (Klemensi köprüleyiniz)
S3B : Makine dairesindeki acil stop butonu
A
1
S4A :
S4B :
S5 :
S6 :
S7 :
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
S7
i
k
108
108
3
TARİH
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
109
S9
S9
S10
Kabin tamponu kontağı
Karşı ağırlık tamponu kontağı
Alt son kesici kontağı
Üst son kesici kontağı
Hız regülatörü kontağı
2
ÇİZİM
S6
107
S11
110
S10
111
S11
112
S12
6
l
e
113
113
120
120
130
130
103 / 10.1:D
RB2 / 10.1:D
E
140
D
S-Kn
S13A S13B S13C
: Kuyu kapağı kontağı
: Gevşek halat kontağı (1:2
askıda)
: Kuyu dibi acil stop butonu
7
S-K1
C
B
S-K1,...,S-Kn : Kat kapısı
kontakları
A
S12
: Hız regülatörü kasnak gergi
kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
GÜVENLİK DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
9 / 11
1
2
3
4
5
E
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
7
l
e
E
D
C
RB2
B
A
3
TARİH
103
869
m
B
k
501
i
C
500
D
RB2
103
501
500
869
9.7:E / RB2
9.7:E / 103
8.7:D / 501
8.7:D / 500
8.7:D / 869
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
10 / 11
1
E
D
C
1
1F
3
3N
4
11
100
1000
103
104
105
106
107
108
109
110
111
112
113
120
130
140
500
501
869
6
MLA
MLB
100B
810
2001
2
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
Kabin ve kabin lambası besleme fazı
Bağımsız sigortadan geçen kabin fazı
Kuyu prizi fazı
Kuyu nötrü
Kuyu aydınlatma fazı
Kumanda panosundaki trafo fazı
Gösterge ve kontrol devreleri müştereği (+) ucu
Gösterge ve kontrol devreleri dönüşü (-) ucu
Makine dairesindeki acil stop buton dönüşü
Kabin tamponu kontağı ve karşı ağırlık tamponu kontağı dönüşü
Alt son kesici kontağı dönüşü
Üst son kesici kontağı dönüşü
Hız regülatörü kontağı dönüşü
Kabin paraşüt fren kontağı dönüşü
Kuyu kapağı kontağı dönüşü
Gevşek halat kontağı dönüşü
Kuyu dibi acil stop buton dönüşü
Hız regülatörü kasnak gergi kontağı dönüşü
Yedek
Seri bağlı stop kontakları dönüşü
Kat kapısı kontakları dönüşü
Kabin kapısı kontakları dönüşü
Revizyonda çalışma aşağı yön sinyal girişi
Revizyonda çalışma yukarı yön sinyal girişi
Revizyona alma anahtarından gelen normal çalışma sinyal girişi
Kuyu üst limiti aşıldı sinyal girişi
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Batem kartı beslemesi
Lirpomp bobini (-) ucu
Lirpomp bobini (+) ucu
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(-24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+180VDC)
i
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3615-1-P
DOSYA
SX-A3-GMV-DY-P-V1
ADN
ADP
AL1, AL2
CANH, CANL
L1, L2, L3
N
N1
P1, P2
PE
RB2
TLFA, TLFB, TLFC, TLFD
U, V, W
IL
IN
UL
UN1
UN
US
VCOM
VDLV
VML
VMD
VMP
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
(+24VDC)
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Şebeke girişleri
(380VAC)
Nötr
(220VAC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Motor termistör sinyal girişleri
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Telefon hattı bağlantı girişleri
Motor sargı çıkışları
(380VAC)
UPS giriş fazı
(220VAC)
UPS giriş nötrü
(220VAC)
UPS çıkış fazı
(220VAC)
UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış fazı
(220VAC)
Valflerin (-) ucu
(-48VDC)
(+48VDC)
Güvenlik valfi ( A3'e uygun )
Hızlı valfinin (+) ucu
(+48VDC)
Aşağı yön valfinin (+) ucu
(+48VDC)
Yukarı yön valfinin (+) ucu
(+48VDC)
k
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
11 / 11
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
T. DESTEK
+90.212. 629 00 08 pbx
+90.542. 591 30 80
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
GMV 3xxxEN, 3xxxS / DLV-A3
BAĞLANTI
SOFT START İLE DOĞRUDAN YOL VERME
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
VAR
H/W
SX/CPU : V1
S/W
SX/CPU : > V1.17
TARİH
12.12.2013
ŞEMA NUMARASI
A3-3620-1-P
DOSYA İSMİ
SX-A3-GMV-SS-GAK-P-V1
SAYFA SAYISI
11
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
WEB
E-Mail
+90.212. 629 11 35
www.mik-el.com
destek@mik-el.com
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
9
G
Θ
M2
D
m
P1
P2
UN2
UN
UL
US
C
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
PE
S-CF
PE
UN2
US
PE
1F N1
FL1
B
N
L1
L2
FL3
S-KF
FL2
S1
FK/6A
L3
PE
IL
IN
S-UF
4
S-SL
FUPS/10A
3 N3
S-LP
DB
: Makine dairesindeki elektrik dağıtım panosu
S1
S-KF
S-UF
S-SL
S-LP
:
:
:
:
:
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
HİDROLİK ASANSÖRLERDE KULLANIMI
S4A S4B
S5
S6
S7
S9
S10
S11
S12
S-Kn
S-K1
100
6
AL2
AL1
130
120
113
112
111
110
109
108
107
106
105
104
RB2
VML
S3B
D
S13A S13B S13C
6
100
P1
P2
P1 / 8.1:A
P2 / 8.1:A
C
SB
S27
B
L4-n
S26
L4-1
DB : Makine dairesindeki elektrik dağıtım panosu
Ana kesici şalter
Kabin fazı anahtarı
UPS fazı anahtarı
Kuyu aydınlatma anahtarı
Kuyu prizi ve aydınlatma anahtarı
VMP
E
J1
FSL/nA
S-CF : Ana kesici şalter (Kumanda panosu ile elektrik dağıtım panosu arası mesafe 1 m. 'den fazla ise
kullanılması gerekmektedir.)
M2 : 3 fazlı asenkron motor
UPS : Kesintisiz güç kaynağı
A
i
VMD
SB
: Kuyu dibi
J1
S27
L4-1,...,L4-n
S26
:
:
:
:
4
F
KB-CF2
REVİZYON KUTUSUNA
AL2
VDLV
AL1
UPS 600VA
M
3~
4
N
(OUT)
3
L
PE
N PE
(IN)
N3
L
VML
VMP
VMD
VCOM
VDLV
UN2
UN
UL
US
UN1
UL
PE
IN
IL
IN
N1
IL
1F
PE
W
V
U
L3
L2
L1
N
E
103
k
99
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
AL2
6
l
e
AL1
130
120
113
112
111
US
UL
UL
UN
UN1
UN2
IN
IN
IL
IL
G
PE
8
7
110
109
99
103
VMP
VML
6
RB2
104
105
106
107
108
5
VMD
UL
UL
US
PE
IL
IL
IN
IN
UN1
UN2
UN
N1
1F
4
VCOM
VDLV
3
PE
W
V
U
L3
2
L2
L1
N
1
Kuyu
Kuyu
Kuyu
Kuyu
prizi
aydınlatma anahtarı
aydınlatma lambaları
alarm butonu
5
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
6
KUMANDA PANOSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
S3B : Makine dairesindeki acil stop butonu
S4A : Kabin tamponu kontağı
S4B : Karşı ağırlık tamponu kontağı
S5
: Alt son kesici kontağı
S6
: Üst son kesici kontağı
S7
: Hız regülatörü kontağı
S9
: Kuyu kapağı kontağı
S10 : Gevşek halat kontağı (1:2 askıda)
S11 : Kuyu dibi acil stop butonu
S12 : Hız regülatörü kasnak gergi kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
S-K1,...,S-Kn : Kat kapısı kontakları
7
A
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
SAYFA
2 / 11
1
2
3
4
FT / 4A (C)
TR1
220VAC
E
5
6
F18/6A (B)
380VA
20VAC
18VAC (80VA)
0
k
0
230VAC (150VA)
5
3
1
B
H1
S3
A
S2 : Panodaki termik
manyetik devre
kesici
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
1
1F
UN
ADN
US
UN1
UN2
UL
UL
IN
IN
IL
IL
L1
L2
L3
N
FP / 2A (C)
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
/ 8.1:E
KBT
4.7:D
14
AC
VS11 / 4.1:E
AC
V10
/ 7.1:D
D
11 / 9.1:E
10A / 4.1:E
LRB
/ 4.1:E
UN / 4.1:D
N / 4.1:E
L3 / 4.1:E
L2 / 4.1:E
L1 / 4.1:E
C
TELEFON
B
A
TR1 : Ana besleme ve yalıtım trafosu
H1 : Pano aydınlatma lambası
S3 : Pano aydınlatma anahtarı
3
TARİH
9AC2
11
100B
I>
DV11
1000V/35A
TLFA
TLFB
TLFC
TLFD
I>
AL1
AL1
AL2
AL2
S2
I>
m
İSTEĞE BAĞLI
2
PE
PE
PE
4
ADP
6
N1
N1
C
i
FDP/ 2A (C)
US
UN
N
L3
L2
L1
F11/1A (B)
0
FLIR / 2A (B)
US
1000 / 6.1:E
9AC1 / 8.1:E
AC
55VAC (130VA)
0
l
e
E
100 / 5.1:E
AC
FV/4A (B)
D
D100
1000V/35A
0
9VAC (20VA)
F9/2A
7
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ BESLEME, AYDINLATMA
VE FAN DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3 / 11
3
4
L3
L2
L1
N
L3
L2
L1
L3
L2
L1
3.7:C / N
3.7:D / 10A
3.7:D / VS11
3.7:C / LRB
3.7:C / UN
3.7:C /
3.7:C /
3.7:C /
5
6
PMD
1
2
N
10A
V11
LRB
UN
1
3
5
KU2
5.5:C
2
4
6
1
3
5
D
KU2-1
00
73
1
W1
V1
A
KU2
74 5.5:C
05
W
m
V
U
B
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
i
04
SOFT START
03
C
6
L1
72
5.5:C 71
U1
KU2
4
L2
01
2
L3
5.6:C
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
l
e
E
TP / 8.1:B
N / 8.1:B
10A / 8.1:B
V11 / 7.1:D
A1
KBT
220VAC
11
KLIR
14 8.1:D
D2000
AC
A2
11
14 3.7:D
D
AC
1000V/35A
U
S14K300
C
B
A
PMD : Faz koruma ve faz
sırası rölesi
3
TARİH
k
7
P1
P2
810
E
2
2001
1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
MOTOR BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4 / 11
1
2
3
4
5
6
l
e
E
K11
22
21
K12
21
5.2:C
3.7:E /
100
D
62
KU2
5.5:C
C
C1
C2
A1
680nF/630V
680nF/630V
K11
R1
61
R2
A2
100R/2W
K12
A2
100R/2W
m
1
3
5
21
62
72
B
A
2
4
6
22
61
71
7.4:C
7.5:C
7.4:C
5.4:E
5.5:C
8.2:C
K11 :
K12 :
K21 :
KU2 :
KU2-1 :
1
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
2
4
6
22
1
3
5
21
7.4:C
7.5:C
7.4:C
5.4:E
22
C3
680nF/630V
R3
100R/2W
21
5.4:C
KU2
31
32
5.5:C
KU2-1
32
31
5.6:C
k
C4
A1
680nF/630V
K21
R4
A2
5.2:C
680nF/630V
KU2
R5
A2
1
3
5
32
62
72
73
/ 8.1:E
100 / 6.1:E
D
R11 / 8.1:D
R21 / 8.1:C
RU2 / 8.1:D
61
C5
A1
2 7.4:C
4 7.5:C
22 5.4:E
KRU
62
K11
100R/2W
1
3
21
E
C
A1
KU2-1
A2
100R/2W
10B
2
4
6
31
61
71
74
4.2:D
4.2:D
4.2:D
5.4:E
5.3:C
4.1:C
4.2:C
1
3
5
31
2
4
6
32
/ 8.1:B
4.2:D
4.2:D
4.2:D
5.5:E
B
A
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü
Yukarı yön kontaktörü
2
ÇİZİM
i
A1
K21
22
5.3:C
7
3
TARİH
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ KONTAKTÖR DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5 / 11
1
2
3
4
5
E
100
1000
5.7:E / 100
3.7:E / 1000
140
120
KRL
RSB
k
RMB
RMA
100
1000
D
i
C
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
KLA
KLB
KLB
KLC
DSB V3
KSB2
KLB
KLA
KLA
l
e
E
100 / 8.1:E
1000 / 8.1:E
140 / 7.1:D
120 / 8.1:D
KRL / 8.1:E
RSB / 8.1:E
RMB / 8.1:E
RMA / 8.1:E
D
C
B
A
3
TARİH
K20
K40
KLC
KMB
7
MLA
MLB
m
B
RMA
RMB
RSB
KRL
SLA
SLB
KMA
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
DSB KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6 / 11
1
2
3
4
5
10 hatlı yassı
kablo
D
4.7:E / V11
6.7:E / 140
3.7:D / V10
i
1
K11
C
5.2:C
2
2
K12
5.3:C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
COM
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
VMD
K3
K4
3A
3C
k
5
3
K11
5.2:C
6
6
K12
1
K21
5.4:C
5.3:C
2
5
VDLV
K11
5.2:C
3
K21
5.4:C
K12
5.3:C
VMP
4
4
7
l
e
SV2
4
HİDROLİK ASANSÖRLERDE KULLANIMI
/ 8.1:A
E
D
VS11 / 8.1:C
140 / 8.1:E
3A / 8.1:D
C
4
3
VML
B
VCOM : Valflerin (-) ucu
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
3
TARİH
1
K2
2A
2C
1A
1C
K1
SV2
SX/RLK V1
4A
4C
E
6
A
5
RLK KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7 / 11
3
4
140
130
120
11
14 4.6:D
5.7:D / R11
5.7:D / RU2
K1
1A
2A
12C
7.7:D / 3A
7.7:D / VS11
5.7:D / R21
K11
71
K2
3A
3C
4A
4C
72
5.2:C
i
K3
K4
5K
5A
5C
6A
6C
C
K5
K6
7K
7C
m
5.7:B /
10B
10A
120
130
140
10B
120
130
140
10B
X1
X2
Gruptaki
diğer
asansör
sistemine
gider
SV2 SV1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
D
032
031
12
02
1000
GB3
GB2
GB1
GB0
1000
Gösterge
bağlantıları
için lütfen
SX-KAT-V1
şema setine
bakınız.
1X
-X
G
F
E
D
C
B
A
100
C
SV5
SV6
Kullanılmayacak!
KSA sistem için girişler
6 / 9.1:E
140 / 9.1:E
130 / 9.1:E
120 / 9.1:E
500 / 10.1:D
501 / 10.1:D
869 / 10.1:D
870 / 10.1:D
B
Kullanılmayacak!
SV3 SV4
K-DP : Makara dairesindeki deprem kontağı
K-YN : Makara dairesindeki yangın kontağı
816
100
806
Çağrı bağlantıları için lütfen
SX-KAT-V1 şema setine bakınız.
K-DP
K-YN
A
KB-CF1
REVİZYON KUTUSUNA
1
Aşağı yön girişleri
E
501
869
870
KS sistem için girişler
Yukarı yön girişleri
SV2
P1
P2
7.7:E / SV2
2.9:C / P1
2.9:C / P2
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
A
S/W V1.17
l
e
100 / 9.1:E
P1
P2
10A
142
817
818
1000
CANL
CANH
1000
100
100
B
4.7:E /
K7
220
N
k
SX/CPU V1
817
818
1000
CANL
CANH
1000
100
100
4.7:E / TP
4.7:E / N
7
6
140
130
120
500
BOŞ
BOŞ
BOŞ
BOŞ
D
1N4007
BOŞ
BOŞ
BOŞ
BOŞ
A2 24VDC
D1
100
1000
9AC1
9AC2
KLIR
MLA
MLB
IN1
IN2
OUT1
OUT2
A1
301
302
303
304
305
306
202
203
204
205
206
207
120
140
130
120
P100
1000
201
202
203
204
205
206
207
208
209
210
211
212
6.7:E / KRL
6.7:D / RMB
6.7:D / RMA
5.7:E / KRU
7.7:D / 140
6.7:E /
6
100
9AC2
9AC1
1000
RSB
OUT1
KRL
RMB
RMA
KRU
500
501
869
870
KRU
E
5
100
P1
P2
2
806
816
100
1
6.7:E / 100
3.7:E / 9AC2
3.7:E / 9AC1
6.7:E / 1000
6.7:D / RSB
UYARI !
Sistem haberleşmesinin sağlıklı çalışabilmesi için bu terminal
grubunun gösterilen sırada ve birarada olması gerekmektedir.
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
SX/CPU KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8 / 11
1
E
2
3
4
5
103
RB2
108
140
130
120
140
130
120
8.7:E / 140
8.7:E / 130
8.7:D / 120
3.7:D / 11
8.7:E / 100
8.7:E / 6
11
100
6
S3A
6
D
100
99
103
S3B
RB2
104
S4A
S4B
105
S5
C
m
106
S6
107
S7
i
14.2.1.4.c 'ye uygun olarak geri alma
çalışmada köprülenecek kontaklar
B
VAR
YOK (Klemensi köprüleyiniz)
S3A : Panodaki acil stop butonu
S3B : Makine dairesindeki acil stop butonu
A
1
S4A :
S4B :
S5 :
S6 :
S7 :
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
k
108
108
3
TARİH
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
109
S9
S9
S10
Kabin tamponu kontağı
Karşı ağırlık tamponu kontağı
Alt son kesici kontağı
Üst son kesici kontağı
Hız regülatörü kontağı
2
ÇİZİM
107
S11
110
S10
111
S11
112
S12
6
l
e
113
113
120
120
130
130
103 / 10.1:D
RB2 / 10.1:D
108 / 10.1:D
140
D
S-K1
C
B
S-K1,...,S-Kn : Kat kapısı
kontakları
A
S12
: Hız regülatörü kasnak gergi
kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
E
S-Kn
S13A S13B S13C
: Kuyu kapağı kontağı
: Gevşek halat kontağı (1:2
askıda)
: Kuyu dibi acil stop butonu
7
5
GÜVENLİK DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
9 / 11
1
2
3
4
5
6
l
e
E
5
3
1
869
869
i
m
A
869
C
B
2-3
103
108
501
501
108
k
1-3
S29
1-4
2-4
1-3
2-3
S30
500
8.7:D /
2-4
501
S28
1-4
E
D
C
B
RS1
2
RB2
4
103
6
500
500
RB2
870
D
RB2
103
108
501
500
870
9.7:E / RB2
9.7:E / 103
9.7:E / 108
8.7:D / 501
8.7:D / 500
8.7:D / 870
7
A
S28 : Panodaki geri alma anahtarı
S29 : Panodaki aşağı yönde geri alma butonu
S30 : Panodaki yukarı yönde geri alma butonu
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
10 / 11
1
E
D
C
1
1F
3
3N
4
99
100
1000
103
104
105
106
107
108
109
110
111
112
113
120
130
140
500
501
869
6
MLA
MLB
100B
810
2001
2
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
Kabin ve kabin lambası besleme fazı
Bağımsız sigortadan geçen kabin fazı
Kuyu prizi fazı
Kuyu nötrü
Kuyu aydınlatma fazı
Panodaki acil stop buton dönüşü
Gösterge ve kontrol devreleri müştereği (+) ucu
Gösterge ve kontrol devreleri dönüşü (-) ucu
Makine dairesindeki acil stop buton dönüşü
Kabin tamponu kontağı ve karşı ağırlık tamponu kontağı dönüşü
Alt son kesici kontağı dönüşü
Üst son kesici kontağı dönüşü
Hız regülatörü kontağı dönüşü
Kabin paraşüt fren kontağı dönüşü
Kuyu kapağı kontağı dönüşü
Gevşek halat kontağı dönüşü
Kuyu dibi acil stop buton dönüşü
Hız regülatörü kasnak gergi kontağı dönüşü
Yedek
Seri bağlı stop kontakları dönüşü
Kat kapısı kontakları dönüşü
Kabin kapısı kontakları dönüşü
Revizyonda çalışma aşağı yön sinyal girişi
Revizyonda çalışma yukarı yön sinyal girişi
Revizyona alma anahtarından gelen normal çalışma sinyal girişi
Kuyu üst limiti aşıldı sinyal girişi
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Batem kartı beslemesi
Lirpomp bobini (-) ucu
Lirpomp bobini (+) ucu
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(-24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+180VDC)
i
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3620-1-P
DOSYA
SX-A3-GMV-SS-GAK-P-V1
ADN
ADP
AL1, AL2
CANH, CANL
L1, L2, L3
N
N1
P1, P2
PE
RB2
RS1
TLFA, TLFB, TLFC, TLFD
U, V, W
IL
IN
UL
UN1
UN
US
VCOM
VDLV
VML
VMD
VMP
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
(+24VDC)
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Şebeke girişleri
(380VAC)
Nötr
(220VAC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Motor termistör sinyal girişleri
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Revizyon anahtarı üzerindeki güvenlik (stop) devresi kontakları dönüşü
(220VAC)
Telefon hattı bağlantı girişleri
(380VAC)
Motor sargı çıkışları
UPS giriş fazı
(220VAC)
UPS giriş nötrü
(220VAC)
UPS çıkış fazı
(220VAC)
UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış fazı
(220VAC)
Valflerin (-) ucu
(-48VDC)
(+48VDC)
Güvenlik valfi ( A3'e uygun )
Hızlı valfinin (+) ucu
(+48VDC)
Aşağı yön valfinin (+) ucu
(+48VDC)
Yukarı yön valfinin (+) ucu
(+48VDC)
k
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
11 / 11
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
T. DESTEK
+90.212. 629 00 08 pbx
+90.542. 591 30 80
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
GMV 3xxxEN, 3xxxS / DLV-A3
BAĞLANTI
SOFT START İLE DOĞRUDAN YOL VERME
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
YOK
H/W
SX/CPU : V1
S/W
SX/CPU : > V1.17
TARİH
12.12.2013
ŞEMA NUMARASI
A3-3625-1-P
DOSYA İSMİ
SX-A3-GMV-SS-P-V1
SAYFA SAYISI
11
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
WEB
E-Mail
+90.212. 629 11 35
www.mik-el.com
destek@mik-el.com
9
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
G
Θ
M2
D
m
P1
P2
UN2
UN
UL
US
C
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
N
L1
L2
L3 UL UN
PE
S-CF
PE
UN2
US
PE
1F N1
FL1
B
N
L1
L2
FL3
S-KF
FL2
S1
FK/6A
L3
PE
IL
IN
S-UF
4
S-SL
FUPS/10A
3 N3
S-LP
DB
: Makine dairesindeki elektrik dağıtım panosu
S1
S-KF
S-UF
S-SL
S-LP
:
:
:
:
:
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
HİDROLİK ASANSÖRLERDE KULLANIMI
S4A S4B
S5
S6
S7
S9
S10
S11
S12
S-Kn
S-K1
100
6
AL2
AL1
130
120
113
112
111
110
109
108
107
106
105
104
RB2
VML
S3B
D
S13A S13B S13C
6
100
P1
P2
P1 / 8.1:A
P2 / 8.1:A
C
SB
S27
B
L4-n
S26
L4-1
DB : Makine dairesindeki elektrik dağıtım panosu
Ana kesici şalter
Kabin fazı anahtarı
UPS fazı anahtarı
Kuyu aydınlatma anahtarı
Kuyu prizi ve aydınlatma anahtarı
VMP
E
J1
FSL/nA
S-CF : Ana kesici şalter (Kumanda panosu ile elektrik dağıtım panosu arası mesafe 1 m. 'den fazla ise
kullanılması gerekmektedir.)
M2 : 3 fazlı asenkron motor
UPS : Kesintisiz güç kaynağı
A
i
VMD
SB
: Kuyu dibi
J1
S27
L4-1,...,L4-n
S26
:
:
:
:
4
F
KB-CF2
REVİZYON KUTUSUNA
AL2
VDLV
AL1
UPS 600VA
M
3~
4
N
(OUT)
3
L
PE
N PE
(IN)
N3
L
VML
VMP
VMD
VCOM
VDLV
UN2
UN
UL
US
UN1
UL
PE
IN
IL
IN
N1
IL
1F
PE
W
V
U
L3
L2
L1
N
E
103
k
11
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
AL2
6
l
e
AL1
130
120
113
112
111
US
UL
UL
UN
UN1
UN2
IN
IN
IL
IL
G
PE
8
7
110
109
11
103
VMP
VML
6
RB2
104
105
106
107
108
5
VMD
UL
UL
US
PE
IL
IL
IN
IN
UN1
UN2
UN
N1
1F
4
VCOM
VDLV
3
PE
W
V
U
L3
2
L2
L1
N
1
Kuyu
Kuyu
Kuyu
Kuyu
prizi
aydınlatma anahtarı
aydınlatma lambaları
alarm butonu
5
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
6
KUMANDA PANOSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
S3B : Makine dairesindeki acil stop butonu
S4A : Kabin tamponu kontağı
S4B : Karşı ağırlık tamponu kontağı
S5
: Alt son kesici kontağı
S6
: Üst son kesici kontağı
S7
: Hız regülatörü kontağı
S9
: Kuyu kapağı kontağı
S10 : Gevşek halat kontağı (1:2 askıda)
S11 : Kuyu dibi acil stop butonu
S12 : Hız regülatörü kasnak gergi kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
S-K1,...,S-Kn : Kat kapısı kontakları
7
A
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
SAYFA
2 / 11
1
2
3
4
FT / 4A (C)
TR1
220VAC
E
5
6
F18/6A (B)
380VA
20VAC
18VAC (80VA)
0
k
0
230VAC (150VA)
5
3
1
B
H1
S3
A
S2 : Panodaki termik
manyetik devre
kesici
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
1
1F
UN
ADN
US
UN1
UN2
UL
UL
IN
IN
IL
IL
L1
L2
L3
N
FP / 2A (C)
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
/ 8.1:E
KBT
4.7:D
14
AC
VS11 / 4.1:E
AC
V10
/ 7.1:D
D
11 / 9.1:E
10A / 4.1:E
LRB
/ 4.1:E
UN / 4.1:D
N / 4.1:E
L3 / 4.1:E
L2 / 4.1:E
L1 / 4.1:E
C
TELEFON
B
A
TR1 : Ana besleme ve yalıtım trafosu
H1 : Pano aydınlatma lambası
S3 : Pano aydınlatma anahtarı
3
TARİH
9AC2
11
100B
I>
DV11
1000V/35A
TLFA
TLFB
TLFC
TLFD
I>
AL1
AL1
AL2
AL2
S2
I>
m
İSTEĞE BAĞLI
2
PE
PE
PE
4
ADP
6
N1
N1
C
i
FDP/ 2A (C)
US
UN
N
L3
L2
L1
F11/1A (B)
0
FLIR / 2A (B)
US
1000 / 6.1:E
9AC1 / 8.1:E
AC
55VAC (130VA)
0
l
e
E
100 / 5.1:E
AC
FV/4A (B)
D
D100
1000V/35A
0
9VAC (20VA)
F9/2A
7
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ BESLEME, AYDINLATMA
VE FAN DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3 / 11
3
4
L3
L2
L1
N
L3
L2
L1
L3
L2
L1
3.7:C / N
3.7:D / 10A
3.7:D / VS11
3.7:C / LRB
3.7:C / UN
3.7:C /
3.7:C /
3.7:C /
5
6
PMD
1
2
N
10A
V11
LRB
UN
1
3
5
KU2
5.5:C
2
4
6
1
3
5
D
KU2-1
00
73
1
W1
V1
A
KU2
74 5.5:C
05
W
m
V
U
B
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
i
04
SOFT START
03
C
6
L1
72
5.5:C 71
U1
KU2
4
L2
01
2
L3
5.6:C
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
l
e
E
TP / 8.1:B
N / 8.1:B
10A / 8.1:B
V11 / 7.1:D
A1
KBT
220VAC
11
KLIR
14 8.1:D
D2000
AC
A2
11
14 3.7:D
D
AC
1000V/35A
U
S14K300
C
B
A
PMD : Faz koruma ve faz
sırası rölesi
3
TARİH
k
7
P1
P2
810
E
2
2001
1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
MOTOR BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4 / 11
1
2
3
4
5
6
l
e
E
K11
22
21
K12
21
5.2:C
3.7:E /
100
D
62
KU2
5.5:C
C
C1
C2
A1
680nF/630V
680nF/630V
K11
R1
61
R2
A2
100R/2W
K12
A2
100R/2W
m
1
3
5
21
62
72
B
A
2
4
6
22
61
71
7.4:C
7.5:C
7.4:C
5.4:E
5.5:C
8.2:C
K11 :
K12 :
K21 :
KU2 :
KU2-1 :
1
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
2
4
6
22
1
3
5
21
7.4:C
7.5:C
7.4:C
5.4:E
22
C3
680nF/630V
R3
100R/2W
21
5.4:C
KU2
31
32
5.5:C
KU2-1
32
31
5.6:C
k
C4
A1
680nF/630V
K21
R4
A2
5.2:C
680nF/630V
KU2
R5
A2
1
3
5
32
62
72
73
/ 8.1:E
100 / 6.1:E
D
R11 / 8.1:D
R21 / 8.1:C
RU2 / 8.1:D
61
C5
A1
2 7.4:C
4 7.5:C
22 5.4:E
KRU
62
K11
100R/2W
1
3
21
E
C
A1
KU2-1
A2
100R/2W
10B
2
4
6
31
61
71
74
4.2:D
4.2:D
4.2:D
5.4:E
5.3:C
4.1:C
4.2:C
1
3
5
31
2
4
6
32
/ 8.1:B
4.2:D
4.2:D
4.2:D
5.5:E
B
A
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Aşağı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü (EN 60947-4-1 'e uygun 9A 'lik mini kontaktör)
Yukarı yön kontaktörü
Yukarı yön kontaktörü
2
ÇİZİM
i
A1
K21
22
5.3:C
7
3
TARİH
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KUMANDA PANOSUNDAKİ KONTAKTÖR DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5 / 11
1
2
3
4
5
E
100
1000
5.7:E / 100
3.7:E / 1000
140
120
KRL
RSB
k
RMB
RMA
100
1000
D
i
C
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
KLA
KLB
KLB
KLC
DSB V3
KSB2
KLB
KLA
KLA
l
e
E
100 / 8.1:E
1000 / 8.1:E
140 / 7.1:D
120 / 8.1:D
KRL / 8.1:E
RSB / 8.1:E
RMB / 8.1:E
RMA / 8.1:E
D
C
B
A
3
TARİH
K20
K40
KLC
KMB
7
MLA
MLB
m
B
RMA
RMB
RSB
KRL
SLA
SLB
KMA
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
DSB KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6 / 11
1
2
3
4
5
10 hatlı yassı
kablo
D
4.7:E / V11
6.7:E / 140
3.7:D / V10
i
1
K11
C
5.2:C
2
2
K12
5.3:C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
COM
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
VMD
K3
K4
3A
3C
k
5
3
K11
5.2:C
6
6
K12
1
K21
5.4:C
5.3:C
2
5
VDLV
K11
5.2:C
3
K21
5.4:C
K12
5.3:C
VMP
4
4
7
l
e
SV2
4
HİDROLİK ASANSÖRLERDE KULLANIMI
/ 8.1:A
E
D
VS11 / 8.1:C
140 / 8.1:E
3A / 8.1:D
C
4
3
VML
B
VCOM : Valflerin (-) ucu
VDLV : Güvenlik valfi ( A3'e uygun )
VMD : Aşağı yön valfi
VMP : Yukarı yön valfi
VML : Hızlı valfi
3
TARİH
1
K2
2A
2C
1A
1C
K1
SV2
SX/RLK V1
4A
4C
E
6
A
5
RLK KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7 / 11
3
4
140
130
120
11
14 4.6:D
5.7:D / R11
5.7:D / RU2
K1
1A
2A
12C
7.7:D / 3A
7.7:D / VS11
5.7:D / R21
K11
71
K2
3A
3C
4A
4C
72
5.2:C
i
K3
K4
5K
5A
5C
6A
6C
C
K5
K6
7K
7C
m
5.7:B /
10B
10A
120
130
140
10B
120
130
140
10B
X1
X2
Gruptaki
diğer
asansör
sistemine
gider
SV2 SV1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
3
TARİH
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
D
032
031
12
02
1000
GB3
GB2
GB1
GB0
1000
Gösterge
bağlantıları
için lütfen
SX-KAT-V1
şema setine
bakınız.
1X
-X
G
F
E
D
C
B
A
100
C
SV5
SV6
Kullanılmayacak!
KSA sistem için girişler
6 / 9.1:E
140 / 9.1:E
130 / 9.1:E
120 / 9.1:E
500 / 10.1:D
501 / 10.1:D
869 / 10.1:D
B
Kullanılmayacak!
SV3 SV4
K-DP : Makara dairesindeki deprem kontağı
K-YN : Makara dairesindeki yangın kontağı
816
100
806
Çağrı bağlantıları için lütfen
SX-KAT-V1 şema setine bakınız.
K-DP
K-YN
A
KB-CF1
REVİZYON KUTUSUNA
1
Aşağı yön girişleri
E
501
869
KS sistem için girişler
Yukarı yön girişleri
SV2
P1
P2
7.7:E / SV2
2.9:C / P1
2.9:C / P2
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
A
S/W V1.17
l
e
100 / 9.1:E
P1
P2
10A
142
817
818
1000
CANL
CANH
1000
100
100
B
4.7:E /
K7
220
N
k
SX/CPU V1
817
818
1000
CANL
CANH
1000
100
100
4.7:E / TP
4.7:E / N
7
6
140
130
120
500
BOŞ
BOŞ
BOŞ
BOŞ
D
1N4007
BOŞ
BOŞ
BOŞ
BOŞ
A2 24VDC
D1
100
1000
9AC1
9AC2
KLIR
MLA
MLB
IN1
IN2
OUT1
OUT2
A1
301
302
303
304
305
306
202
203
204
205
206
207
120
140
130
120
P100
1000
201
202
203
204
205
206
207
208
209
210
211
212
6.7:E / KRL
6.7:D / RMB
6.7:D / RMA
5.7:E / KRU
7.7:D / 140
6.7:E /
6
100
9AC2
9AC1
1000
RSB
OUT1
KRL
RMB
RMA
KRU
500
501
869
870
KRU
E
5
100
P1
P2
2
806
816
100
1
6.7:E / 100
3.7:E / 9AC2
3.7:E / 9AC1
6.7:E / 1000
6.7:D / RSB
UYARI !
Sistem haberleşmesinin sağlıklı çalışabilmesi için bu terminal
grubunun gösterilen sırada ve birarada olması gerekmektedir.
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
SX/CPU KARTININ BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8 / 11
1
E
2
3
4
5
103
RB2
140
130
120
140
130
120
11
8.7:E / 140
8.7:E / 130
8.7:D / 120
3.7:D / 11
8.7:E / 100
8.7:E / 6
100
6
6
100
11
103
RB2
104
105
106
107
D
S3B
S4A
S4B
S5
C
B
m
VAR
YOK (Klemensi köprüleyiniz)
S3B : Makine dairesindeki acil stop butonu
A
1
S4A :
S4B :
S5 :
S6 :
S7 :
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
S7
i
k
108
108
3
TARİH
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
109
S9
S9
S10
Kabin tamponu kontağı
Karşı ağırlık tamponu kontağı
Alt son kesici kontağı
Üst son kesici kontağı
Hız regülatörü kontağı
2
ÇİZİM
S6
107
S11
110
S10
111
S11
112
S12
6
l
e
113
113
120
120
130
130
103 / 10.1:D
RB2 / 10.1:D
E
140
D
S-Kn
S13A S13B S13C
: Kuyu kapağı kontağı
: Gevşek halat kontağı (1:2
askıda)
: Kuyu dibi acil stop butonu
7
S-K1
C
B
S-K1,...,S-Kn : Kat kapısı
kontakları
A
S12
: Hız regülatörü kasnak gergi
kontağı
S13A : Aşırı yağ sıcaklığı kontağı
S13B : Aşırı basınç kontağı
S13C : Patlak hortum kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
GÜVENLİK DEVRELERİ
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
9 / 11
1
2
3
4
5
E
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
7
l
e
E
D
C
RB2
B
A
3
TARİH
103
869
m
B
k
501
i
C
500
D
RB2
103
501
500
869
9.7:E / RB2
9.7:E / 103
8.7:D / 501
8.7:D / 500
8.7:D / 869
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
10 / 11
1
E
D
C
1
1F
3
3N
4
11
100
1000
103
104
105
106
107
108
109
110
111
112
113
120
130
140
500
501
869
6
MLA
MLB
100B
810
2001
2
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
3
Kabin ve kabin lambası besleme fazı
Bağımsız sigortadan geçen kabin fazı
Kuyu prizi fazı
Kuyu nötrü
Kuyu aydınlatma fazı
Kumanda panosundaki trafo fazı
Gösterge ve kontrol devreleri müştereği (+) ucu
Gösterge ve kontrol devreleri dönüşü (-) ucu
Makine dairesindeki acil stop buton dönüşü
Kabin tamponu kontağı ve karşı ağırlık tamponu kontağı dönüşü
Alt son kesici kontağı dönüşü
Üst son kesici kontağı dönüşü
Hız regülatörü kontağı dönüşü
Kabin paraşüt fren kontağı dönüşü
Kuyu kapağı kontağı dönüşü
Gevşek halat kontağı dönüşü
Kuyu dibi acil stop buton dönüşü
Hız regülatörü kasnak gergi kontağı dönüşü
Yedek
Seri bağlı stop kontakları dönüşü
Kat kapısı kontakları dönüşü
Kabin kapısı kontakları dönüşü
Revizyonda çalışma aşağı yön sinyal girişi
Revizyonda çalışma yukarı yön sinyal girişi
Revizyona alma anahtarından gelen normal çalışma sinyal girişi
Kuyu üst limiti aşıldı sinyal girişi
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Kilit açma bölgesi şalteri sinyal girişi (Darbeye ve titreşime dayanıklı)
Batem kartı beslemesi
Lirpomp bobini (-) ucu
Lirpomp bobini (+) ucu
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(-24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+180VDC)
i
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
12.12.2013
ŞEMA NO
A3-3625-1-P
DOSYA
SX-A3-GMV-SS-P-V1
ADN
ADP
AL1, AL2
CANH, CANL
L1, L2, L3
N
N1
P1, P2
PE
RB2
TLFA, TLFB, TLFC, TLFD
U, V, W
IL
IN
UL
UN1
UN
US
VCOM
VDLV
VML
VMD
VMP
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
(+24VDC)
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Şebeke girişleri
(380VAC)
Nötr
(220VAC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Motor termistör sinyal girişleri
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Telefon hattı bağlantı girişleri
Motor sargı çıkışları
(380VAC)
UPS giriş fazı
(220VAC)
UPS giriş nötrü
(220VAC)
UPS çıkış fazı
(220VAC)
UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış nötrü
(220VAC)
Ana kesici şalter kontağından geçen UPS çıkış fazı
(220VAC)
Valflerin (-) ucu
(-48VDC)
(+48VDC)
Güvenlik valfi ( A3'e uygun )
Hızlı valfinin (+) ucu
(+48VDC)
Aşağı yön valfinin (+) ucu
(+48VDC)
Yukarı yön valfinin (+) ucu
(+48VDC)
k
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
GMV 3xxxEN, 3xxxS / DLV-A3
SOFT START İLE DOĞRUDAN YOL VERME
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
YOK
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
11 / 11
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
+90.212. 629 00 08 pbx
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
HİDROLİK
BAĞLANTI
REVİZYON KUTUSU
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
VAR
H/W
SX/CAB : V1
S/W
SX/CAB : V1.01
TARİH
23.10.2012
ŞEMA NUMARASI
1001-R
DOSYA İSMİ
SX-HD-U-DSB-GAK-R-V1
SAYFA SAYISI
8
ÇİZİM
MURAT TEZEL
KONTROL
M. SELÇOK
FAKS
+90.212. 629 11 35
WEB
www.mik-el.com
G
4
:
:
:
:
:
:
:
:
5
Kilit açma bölgesi şalterleri (Darbeye ve titreşime dayanıklı)
Alt zorunlu yavaşlatıcı şalter
Alt zorunlu yavaşlatıcı şalter
Üst zorunlu yavaşlatıcı şalter
Sayıcı ve seviyeleme şalterleri
Gong kiti
Tam yük kontağı
Aşırı yük kontağı
!
6
8
7
S23
H3
BT1
H4
KS1
S25
:
:
:
:
:
:
9
Revizyon kutusu alarm butonu
Kabin lambası
Akü (12V / 1.2Ah)
Kabin acil aydınlatma lambası (max. 2,4W)
Hoparlör (8 ohm)
Kabin intercom butonu
l
e
Sayıcı şalterin MA ucu (sarı renkli kablo) SX/CAB kartının M0 klemensine,
MB ucu (mavi renkli kablo) ise SX/CAB kartının M1 klemensine
bağlanmalıdır
Y1
S23
S-R1
F
MA
(M0)
S-R2
MB
(M1)
S-FL
S-OL
k
1
Sistem "A" asansörü ise
J5
Sistem "B" asansörü ise
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
D
805
804
100
AL2
AL1
1000
100
SR+
SR-
SV31 / 3.1:D
SV32 / 3.1:D
J1 J2 J3 J4
C
X1.1
X1.2
X1.3
X1.4
S/W V1.01
BATEM V3
BT-
1
2
X2.1
X2.2
X2.3
X2.4
X2.5
X2.6
J5
AL1
AL2
Bkz. Sayfa 6/8
805
804
100
/ 4.1:C
/ 4.1:B
B
2
+12V
SR+
SR-
BTBT+
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
AL1
AL2
KB-CF1
KUMANDA PANOSUNA
N1
H3
A
_
J2
HİDROLİK ASANSÖRLERDE KULLANIMI
J3
J4
4
J1
5
J2
J3
+
12V
GB çıkışları kullanılacak ise
7 segment çıkışları kullanılacak ise
J1
3
TARİH
SV22
100
K16
K19
K30
K3
K5
K15
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
869
500
501
114
115
116
117
119
120
130
140
J5
E
100 / 5.1:B
1000 / 6.1:B
PE / 6.1:C
16 hatlı
yassı kablo
L-
L+
KS1
H4
BT1
J4
6
REVİZYON KUTUSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
7
12V
YD : Yedek klemensler
REVİZYON KUTUSU
20 hatlı
yassı kablo
SX/CAB V1
X1
F
1
KB-CF2
KUMANDA PANOSUNA
A
SV21
IN1
OUT1
100
804
805
m
Bkz. Sayfa 5/8
PE
N1
1
ADN
ADP
810
2001
103
RB2
RS1
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
B
Bkz. Sayfa 4/8
107
108
113
103
RB2
RS1
Bkz. Sayfa 5/8
810
2001
ADN
ADP
C
PE
N1
N1
N1
1
1
1
Bkz. Sayfa 6/8
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
SV31
SV32
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
M0
M1
M2
M3
100
100
1000
291
i
D
100
1000
PE
N1
1
PE
N1
1
YD
YD
PE
N1
1
100
1000
291
J3
100
142
817
818
100
PE
N1
1
E
817
818
100
J2
142
817
818
1000
CANL
CANH
1000
100
100
PE
N1
1
100 : Kırmızı kablo
M0 : Sarı kablo
M1 : Mavi kablo
KS2
+12V
S-LB
S25
BT+
AL1
AL2
LL+
S-LA
2001
810
S-MP
G
TLFA
3
S-LA,S-LB
S-R1
S-R1
S-R2
S-MP
KS2
S-FL
S-OL
C
D
2
: Revizyon kutusu prizi
: Revizyon kutusu prizi
: Lirpomp bobini
TLFC
TLFD
1
J2
J3
Y1
INTERCOM
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
SAYFA
2/8
1
2
3
S-401,S-402,...,S-415,S-416 : İç kumanda girişleri
H-401,H-402,...,H-415,H-416 : İç kumanda kayıt lambaları
S-AT
H-32
H-31
H-01
KS3
:
:
:
:
:
4
5
Vatman anahtarı
Yukarı yön lambası
Aşağı yön lambası
Aşırı yük lambası
Aşırı yük alarm sinyali
6
7
l
e
DS-A : Ortak anod gösterge ( 7 segment gösterge )
7 segment çıkışları kullanılacak ise
J1 J2 J3 J4
NOT : SX CPU kartındaki "H05" parametresi 7 segment olarak ayarlanmalıdır!
E
E
DS-C : Ortak katod gösterge ( Gray kod veya binary kod )
k
GB çıkışları kullanılacak ise
J1 J2 J3 J4
NOT : SX CPU kartındaki "H05" parametresi gray veya binary olarak ayarlanmalıdır!
16 hatlı
yassı kablo
D
SV32
SV31
SV32
SV31
100
S-401
S-402
S-415
S-416
i
416
416
415
414
413
412
411
410
409
408
407
406
405
404
403
402
401
1000
100
415
C
m
402
401
B
H-401
H-402
H-415
H-416
1000
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
SV32
1000
01
SX/TRM V1
01
1000
D
DS-A
1000
1000
032
031
H-32
032
H-31
DS-C
H-01
KS3
C
031
100
100
1000
GB0/A
GB1/B
GB2/C
GB3/D
E
F
G
-X
1X
1000
GB0/M0
GB1/M1
GB2/M2
GB3/M3
A
B
C
D
E
F
G
-X
1X
B
DTS
DTO
100
100
DTS / 6.1:B
DTO / 6.1:B
100 / 6.1:B
812
A
S-AT
3
TARİH
SV31
100
DTO
DTS
20 hatlı
yassı kablo
100
812
2.9:C /
2.9:C /
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KABİN TESİSATI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3/8
1
2
3
4
5
E
D
k
Bkz. Sayfa 2/8
107
C
108
113
AL1
2.9:B /
AL2
m
B
115
i
S8
2.9:B /
114
S14
S15
116
S16
YOK (Klemensi köprüleyiniz)
S8 :
S14 :
S15 :
S16 :
S17 :
S19 :
S20 :
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
S19
Kabin paraşüt fren kontağı
Kabin içi acil stop butonu
Kabin üstü acil stop butonu
Kabin gevşek halat kontağı
Kabin çatı kapağı kontağı
Yedek
Yedek
3
TARİH
S17
119
120
S20
130
140
S-FK
7
l
e
E
D
C
Kabin kapısı yok ise
14.2.1.4.c 'ye uygun olarak geri alma
çalışmada köprülenecek kontak
VAR
117
6
B
S-FK : Kabin kapısı
kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
GÜVENLİK DEVRELERİ
A
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4/8
1
2
3
4
5
6
E
D
C
869
m
B
103
6
4
S32
2.9:E /
100
i
500
2
501
1-4
S33
5
3
1
k
Bkz. Sayfa 2/8
2-4
RB2
1-4
2-4
1-3
2-3
7
l
e
E
D
C
RS1
B
S34
1-3
2-3
S32 : Revizyon kutusundaki revizyon anahtarı
S33 : Revizyon kutusundaki aşağı yön butonu
S34 : Revizyon kutusundaki yukarı yön butonu
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
3
TARİH
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
A
5
REVİZYON (BAKIM) KUMANDASI VE GERİ ALMA
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5/8
6
E
ADP : Otomatik kapı fazı
(220VAC)
ADN : Otomatik kapı nötrü
(220VAC)
PE : Topraklama
K3 : Kapı kapama kontağı dönüşü
i
C
/ ADP
/ ADN
2.9:E / PE
/ 100
2/8
2.9:E / 1000
/ K3
/ K5
/ K15
2/8
/ K16
/ K19
/ K30
3.7:A / 100
3.7:A / DTO
3.7:A / DTS
Bkz. Sayfa 2/8
Bkz. Sayfa
Bkz. Sayfa
B
S36
CB
A
CB
: Kabin
S36
S37
S-FT
S-DR
:
:
:
:
S-FT
S-DR
l
e
220VAC
L1 TB1
7
220VAC
N TB4
5
PE
6
- 31, 34, 37 01, 02, 03 6, 8
10
10
I2
1
8
I1
2
12
COM
4
NOT3
NC / 01
5
30
7
NC / 02
33
36
D
C
8
5
220VAC
220VAC
7
220VAC
6
220VAC
17, 18 X6/5, X11-12-13/3 11, 13, 27 5, 8, 11 / J2 5, 8, 11 / X3
X6/4, X6/6
26, 28
3
24
3 / J3
8 / X4
X6/2
5
4 / J3
X6/1
25
9 / X4
15
NOT3
5 / J3
10 / X4
NOT3
16
14
12 / J2
12 / X3
X13-1
6 / J2
6 / X3
19
X11-1
10
7 / J2
7 / X3
X12-1
B
NOT1 : Fermator 40/10 220VAC kapılarda K15 hattı ADP hattına köprülenmelidir
NOT2 : Tam otomatik Fermator VVVF-4 kapılarda K15 hattı 100 hattına, yarı otomatik Fermator VVVF-4
kapılarda K15 hattı ADP hattına köprülenmelidir
NOT3 : Klefer VVVF-4, Siemens AT25 ve Siemens AT18 kapılarda K15 hattı 100 hattına köprülenmelidir
NOT4 : Ake ATK V2 kapılarda K15 hattı +12V hattına köprülenmelidir
NOT5 : Ake ATK V2 kapılarda AC1, AC2 klemensleri 0/220-0/30VAC trafo ile beslenecektir.
P
A
Yukarıdaki tablodan kapı tipine göre bağlantı uçlarını seçiniz
Kapı kapama butonu
Kapı açma butonu
Fotosel
Kapı sıkışma kontağı
1
2
ÇİZİM
7
ADP
NOT5 19
5
1
ADN
NOT5 20
6
PE
- 100 23C, 1C 37 6, 7 31, 34, 37
10
1000
- 25
8
3
K3
KPS 31
2
12
K5
ACS 33
NOT2
K15
NOT4 6 NOT1
5
30
K16
2A 32
33
8
K19
3A 34
36
K30
1A -
m
S37
k
WITTUR HYDRA PLUS
(-24VDC)
KLEFER VVVF-4
(+24VDC)
1000 : Gösterge ve kontrol devreleri dönüşü (-) ucu
FERMATOR VVVF-4
(+24VDC)
100 : Gösterge ve kontrol devreleri müştereği (+) ucu
FERMATOR 40/10 220VAC
(+24VDC)
K30 : Kapı geri açma sinyal girişi
AKE OSMA
(+24VDC)
K19 : Kapı kapama limit sinyal girişi
AKE ATK V2
D
K16 : Kapı açma limit sinyal girişi
KAT KAPILARI OTOMATİK OLMAYAN VE KABİN KAPISI
KARTLI TELESKOPİK VEYA KATLANIR TİP OLAN
K5 : Kapı açma kontağı dönüşü
K15 : Kapı açma ve kapı kapama kontağı müştereği
E
PRISMA VVVF (JAGUAR)
OTOMATİK KAPI KLEMENS AÇIKLAMALARI
7
PRISMA VVVF (FOX)
5
SIEMENS AT25
4
SIEMENS AT18
3
SEMATIC 2000
2
SELCOM RCRE 24 / RC 48
1
MURAT TEZEL
KONTROL M. SELÇOK
3
TARİH
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
OTOMATİK KAPI BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6/8
LD1
LG2
LD2
LD2
MB
LD1
Kat hizası
n. Durak
5
LG1
4
MB
3
MA
2
MA
1
G
12 cm
MB
3...5 cm
MA
LS2
G
12 cm
MB
MA
LS2
E
C
LD2
Mavi (M1)
Sarı (M0)
Kırmızı (100)
MLA
MLB
B
S-R1
(817)
Min. 16cm
LG1
LS1
LD1
MB
MA
m
LD1
12 cm
E
D
LD2
Kat hizası
1. Durak
MB
3...5 cm
MB
i
12 cm
MA
D
MA
Min. 16cm
12 cm
LG1
LD1
MB
MA
LD2
LD2
LG2
MB
MB
LS1
MA
MA
12 cm
k
LD1
Kat hizası
2. Durak
l
e
F
12 cm
LG2
F
Min. 16cm
Min. 16cm
12 cm
C
.MB
12 cm
S-R2
.MA
(818)
(S-MP)
S-LA
S-LB
(MLA)
(MLB)
B
: Siyah renkli mıknatıs
: Kırmızı renkli mıknatıs
KABİN
: Şerit mıknatıs
: Kontak kapalı
A
LG1,LG2 : Kapı ve kilit açık çalışma alt ve üst bölgesi ( LG1 ve LG2 manuel kat kapılı asansörlerde 20 cm'yi, otomatik kabin kapısıyla birlikte
çalışan otomatik kat kapılı asansörlerde ise 35cm'yi aşmamalıdır. )
LS1
: İnişte yavaşlama yolu
LS2
: Çıkışta yavaşlama yolu
LD1
: Aşağı normal seyahatte ve seviye düzeltmede durma yolu (Aşağıya doğru seviye yenilemenin başlayacağı yukarı kaçma payı) (7 cm)
LD2
: Yukarı normal seyahatte ve seviye düzeltmede durma yolu (Yukarıya doğru seviye yenilemenin başlayacağı aşağı kaçma payı) (7 cm)
NOT1
: Şema, 3 durak içindir. Daha yüksek duraklarda S-R2 'nin kontağı, en üst durağın LS2 başlangıç noktasında açılmalıdır
1
2
3
5
MANYETİK ŞALTER VE ŞERİT MIKNATISLARIN YERLEŞTİRİLMESİ
HİDROLİK ASANSÖRLERDE KULLANIMI
ÇİZİM
4
A
MURAT TEZEL
KONTROL M. SELÇOK
TARİH
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
SAYFA
7/8
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve
eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı
izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
1
E
D
C
2
3
: Aşırı yük sinyal çıkışı
01
031
: Aşağı yön oku sinyal çıkışı
: Yukarı yön oku sinyal çıkışı
032
1
: Kabin ve kabin lambası besleme fazı
2
: Kabin lambası fazı
100
: Gösterge ve kontrol devreleri müştereği (+) ucu
100B
: Batem kartı beslemesi
107
: Hız regülatörü kontağı dönüşü
: Kabin paraşüt fren kontağı dönüşü
108
113
: Patlak hortum kontağı dönüşü
114
: Kabin içi acil stop buton dönüşü
115
: Kabin üstü acil stop buton dönüşü
116
: Kabin gevşek halat kontağı dönüşü
: Kabin çatı kapağı kontağı dönüşü
117
: Yedek
119
: Seri bağlı stop kontakları dönüşü
120
: Kat kapısı kontakları dönüşü
130
: Kabin kapısı kontağı dönüşü
140
291
: Gong sinyal çıkışı
401, ..., 416 : İç kumanda girişleri
: Revizyonda çalışma aşağı yön sinyal girişi
500
501
: Revizyonda çalışma yukarı yön sinyal girişi
: Aşırı yük kontağı dönüşü
804
: Tam yük kontağı dönüşü
805
: Lirpomp bobini (-) ucu
810
: Vatman sinyal girişi
812
: Alt zorunlu yavaşlatıcı kontak dönüşü
817
: Üst zorunlu yavaşlatıcı kontak dönüşü
818
: Revizyona alma anahtarından gelen normal çalışma sinyal girişi
869
: Gösterge ve kontrol devreleri dönüşü (-) ucu
1000
: Lirpomp bobini (+) ucu
2001
m
B
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
(+24VDC)
(+24VDC)
(+24VDC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-24VDC)
(+180VDC)
i
23.10.2012
ŞEMA NO
1001-R
DOSYA
SX-HD-U-DSB-GAK-R-V1
A, B, C, D, E, F, G, -X, 1X, 2X
ADN
ADP
AL1, AL2
CANH, CANL
DTO
DTS
GB0, GB1, GB2, GB3
K3
K5
K15
K16
K19
K30
M0
M1
M2, M3
N1
PE
RB2
RS1
TLFA, TLFB, TLFC, TLFD
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
7 segment gösterge sinyal çıkışı
(-24VDC)
Otomatik kapı nötrü
(220VAC)
Otomatik kapı fazı
(220VAC)
Alarm sinyal girişleri
(+24VDC)
Seri haberleşme sinyalleri
(+24VDC)
Kapı açma sinyal girişi
(+24VDC)
Kapı kapama sinyal girişi
(+24VDC)
Gray kod veya binary kod sinyal çıkışları
Kapı kapama kontağı dönüşü
(*)
Kapı açma kontağı dönüşü
(*)
Kapı açma ve kapı kapama kontağı müştereği
(*)
Kapı açma limit sinyal girişi
(+24VDC)
Kapı kapama limit sinyal girişi
(+24VDC)
Kapı geri açma sinyal girişi
(+24VDC)
Gray kod ve sayıcı (MA) konum bilgisi şalterleri dönüşü
(+24VDC)
Gray kod ve sayıcı (MB) konum bilgisi şalterleri dönüşü
(+24VDC)
Gray kod konum bilgisi şalterleri dönüşü
(+24VDC)
Bağımsız sigortadan geçen kabin nötrü
(220VAC)
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü (220VAC)
Revizyon anahtarı üzerindeki güvenlik (stop) devresi kontakları dönüşü
(220VAC)
Telefon hattı bağlantı girişleri
k
(*) : Kullanılan otomatik kapıya göre değişir
E
D
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
VAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8/8
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
+90.212. 629 00 08 pbx
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
HİDROLİK ASANSÖRLERDE KULLANIMI
ÜNİTE
HİDROLİK
BAĞLANTI
REVİZYON KUTUSU
KAPI AÇIK SEVİYELEME
VAR
ERKEN KAPI AÇMA
VAR
VALF GERİLİMİ
< GÜVENLİK DEVRESİ GERİLİMİ
GERİ ALMA KUMANDA
-
H/W
SX/CAB : V1
S/W
SX/CAB : V1.01
TARİH
23.10.2012
ŞEMA NUMARASI
1002-R
DOSYA İSMİ
SX-HD-U-DSB-R-V1
SAYFA SAYISI
8
ÇİZİM
MURAT TEZEL
KONTROL
M. SELÇOK
FAKS
+90.212. 629 11 35
WEB
www.mik-el.com
G
4
:
:
:
:
:
:
:
:
5
Kilit açma bölgesi şalterleri (Darbeye ve titreşime dayanıklı)
Alt zorunlu yavaşlatıcı şalter
Alt zorunlu yavaşlatıcı şalter
Üst zorunlu yavaşlatıcı şalter
Sayıcı ve seviyeleme şalterleri
Gong kiti
Tam yük kontağı
Aşırı yük kontağı
!
6
8
7
S23
H3
BT1
H4
KS1
S25
:
:
:
:
:
:
9
Revizyon kutusu alarm butonu
Kabin lambası
Akü (12V / 1.2Ah)
Kabin acil aydınlatma lambası (max. 2,4W)
Hoparlör (8 ohm)
Kabin intercom butonu
l
e
Sayıcı şalterin MA ucu (sarı renkli kablo) SX/CAB kartının M0 klemensine,
MB ucu (mavi renkli kablo) ise SX/CAB kartının M1 klemensine
bağlanmalıdır
Y1
S23
S-R1
F
MA
(M0)
S-R2
MB
(M1)
S-FL
S-OL
k
1
Sistem "A" asansörü ise
J5
Sistem "B" asansörü ise
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
D
805
804
100
AL2
AL1
1000
100
SR+
SR-
SV31 / 3.1:D
SV32 / 3.1:D
J1 J2 J3 J4
C
X1.1
X1.2
X1.3
X1.4
S/W V1.01
BATEM V3
BT-
1
2
X2.1
X2.2
X2.3
X2.4
X2.5
X2.6
J5
AL1
AL2
Bkz. Sayfa 6/8
805
804
100
/ 4.1:C
/ 4.1:B
B
2
+12V
SR+
SR-
BTBT+
YD1
YD2
YD3
YD4
817
818
1000
CANL
CANH
1000
100
100
AL1
AL2
KB-CF1
KUMANDA PANOSUNA
N1
H3
A
_
J2
HİDROLİK ASANSÖRLERDE KULLANIMI
J3
J4
4
J1
5
J2
J3
+
12V
GB çıkışları kullanılacak ise
7 segment çıkışları kullanılacak ise
J1
3
TARİH
SV22
100
K16
K19
K30
K3
K5
K15
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
869
500
501
114
115
116
117
119
120
130
140
J5
E
100 / 5.1:B
1000 / 6.1:B
PE / 6.1:C
16 hatlı
yassı kablo
L-
L+
KS1
H4
BT1
J4
6
REVİZYON KUTUSUNUN KLEMENSLERİ VE DIŞ BAĞLANTILAR
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
7
12V
YD : Yedek klemensler
REVİZYON KUTUSU
20 hatlı
yassı kablo
SX/CAB V1
X1
F
1
KB-CF2
KUMANDA PANOSUNA
A
SV21
IN1
OUT1
100
804
805
m
Bkz. Sayfa 5/8
PE
N1
1
ADN
ADP
810
2001
103
RB2
107
108
113
120
130
140
869
500
501
MLA
MLB
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
B
Bkz. Sayfa 4/8
107
108
113
Bkz. Sayfa 5/8
103
RB2
810
2001
ADN
ADP
C
PE
N1
N1
N1
1
1
1
Bkz. Sayfa 6/8
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
SV31
SV32
TLFA
TLFB
TLFC
TLFD
AL1
AL2
100B
100
M0
M1
M2
M3
100
100
1000
291
i
D
100
1000
PE
N1
1
PE
N1
1
YD
YD
PE
N1
1
100
1000
291
J3
100
142
817
818
100
PE
N1
1
E
817
818
100
J2
142
817
818
1000
CANL
CANH
1000
100
100
PE
N1
1
100 : Kırmızı kablo
M0 : Sarı kablo
M1 : Mavi kablo
KS2
+12V
S-LB
S25
BT+
AL1
AL2
LL+
S-LA
2001
810
S-MP
G
TLFA
3
S-LA,S-LB
S-R1
S-R1
S-R2
S-MP
KS2
S-FL
S-OL
C
D
2
: Revizyon kutusu prizi
: Revizyon kutusu prizi
: Lirpomp bobini
TLFC
TLFD
1
J2
J3
Y1
INTERCOM
8
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
9
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
SAYFA
2/8
1
2
3
S-401,S-402,...,S-415,S-416 : İç kumanda girişleri
H-401,H-402,...,H-415,H-416 : İç kumanda kayıt lambaları
S-AT
H-32
H-31
H-01
KS3
:
:
:
:
:
4
5
Vatman anahtarı
Yukarı yön lambası
Aşağı yön lambası
Aşırı yük lambası
Aşırı yük alarm sinyali
6
7
l
e
DS-A : Ortak anod gösterge ( 7 segment gösterge )
7 segment çıkışları kullanılacak ise
J1 J2 J3 J4
NOT : SX CPU kartındaki "H05" parametresi 7 segment olarak ayarlanmalıdır!
E
E
DS-C : Ortak katod gösterge ( Gray kod veya binary kod )
k
GB çıkışları kullanılacak ise
J1 J2 J3 J4
NOT : SX CPU kartındaki "H05" parametresi gray veya binary olarak ayarlanmalıdır!
16 hatlı
yassı kablo
D
SV32
SV31
SV32
SV31
100
S-401
S-402
S-415
S-416
i
416
416
415
414
413
412
411
410
409
408
407
406
405
404
403
402
401
1000
100
415
C
m
402
401
B
H-401
H-402
H-415
H-416
1000
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
SV32
1000
01
SX/TRM V1
01
1000
D
DS-A
1000
1000
032
031
H-32
032
H-31
DS-C
H-01
KS3
C
031
100
100
1000
GB0/A
GB1/B
GB2/C
GB3/D
E
F
G
-X
1X
1000
GB0/M0
GB1/M1
GB2/M2
GB3/M3
A
B
C
D
E
F
G
-X
1X
B
DTS
DTO
100
100
DTS / 6.1:B
DTO / 6.1:B
100 / 6.1:B
812
A
S-AT
3
TARİH
SV31
100
DTO
DTS
20 hatlı
yassı kablo
100
812
2.9:C /
2.9:C /
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KABİN TESİSATI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3/8
1
2
3
4
5
E
D
k
Bkz. Sayfa 2/8
107
C
108
113
AL1
2.9:B /
AL2
m
B
VAR
S14
YOK (Klemensi köprüleyiniz)
S8 :
S14 :
S15 :
S16 :
S17 :
S19 :
S20 :
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
S15
116
S16
117
S17
119
S19
120
S20
130
140
S-FK
7
l
e
E
D
C
Kabin kapısı yok ise
Kabin paraşüt fren kontağı
Kabin içi acil stop butonu
Kabin üstü acil stop butonu
Kabin gevşek halat kontağı
Kabin çatı kapağı kontağı
Yedek
Yedek
3
TARİH
115
i
S8
2.9:B /
114
6
B
S-FK : Kabin kapısı
kontağı
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
GÜVENLİK DEVRELERİ
A
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4/8
1
2
3
4
5
E
D
C
869
m
B
103
6
4
S32
2.9:E /
100
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
500
2
501
1-4
S33
5
3
1
2-4
7
l
e
E
D
C
RB2
1-4
2-4
1-3
2-3
B
S34
1-3
2-3
S32 : Revizyon kutusundaki revizyon anahtarı
S33 : Revizyon kutusundaki aşağı yön butonu
S34 : Revizyon kutusundaki yukarı yön butonu
3
TARİH
i
k
Bkz. Sayfa 2/8
6
4
HİDROLİK ASANSÖRLERDE KULLANIMI
A
5
REVİZYON (BAKIM) KUMANDASI BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5/8
6
E
ADP : Otomatik kapı fazı
(220VAC)
ADN : Otomatik kapı nötrü
(220VAC)
PE : Topraklama
K3 : Kapı kapama kontağı dönüşü
i
C
/ ADP
/ ADN
2.9:E / PE
/ 100
2/8
2.9:E / 1000
/ K3
/ K5
/ K15
2/8
/ K16
/ K19
/ K30
3.7:A / 100
3.7:A / DTO
3.7:A / DTS
Bkz. Sayfa 2/8
Bkz. Sayfa
Bkz. Sayfa
B
S36
CB
A
CB
: Kabin
S36
S37
S-FT
S-DR
:
:
:
:
S-FT
S-DR
l
e
220VAC
L1 TB1
7
220VAC
N TB4
5
PE
6
- 31, 34, 37 01, 02, 03 6, 8
10
10
I2
1
8
I1
2
12
COM
4
NOT3
NC / 01
5
30
7
NC / 02
33
36
D
C
8
5
220VAC
220VAC
7
220VAC
6
220VAC
17, 18 X6/5, X11-12-13/3 11, 13, 27 5, 8, 11 / J2 5, 8, 11 / X3
X6/4, X6/6
26, 28
3
24
3 / J3
8 / X4
X6/2
5
4 / J3
X6/1
25
9 / X4
15
NOT3
5 / J3
10 / X4
NOT3
16
14
12 / J2
12 / X3
X13-1
6 / J2
6 / X3
19
X11-1
10
7 / J2
7 / X3
X12-1
B
NOT1 : Fermator 40/10 220VAC kapılarda K15 hattı ADP hattına köprülenmelidir
NOT2 : Tam otomatik Fermator VVVF-4 kapılarda K15 hattı 100 hattına, yarı otomatik Fermator VVVF-4
kapılarda K15 hattı ADP hattına köprülenmelidir
NOT3 : Klefer VVVF-4, Siemens AT25 ve Siemens AT18 kapılarda K15 hattı 100 hattına köprülenmelidir
NOT4 : Ake ATK V2 kapılarda K15 hattı +12V hattına köprülenmelidir
NOT5 : Ake ATK V2 kapılarda AC1, AC2 klemensleri 0/220-0/30VAC trafo ile beslenecektir.
P
A
Yukarıdaki tablodan kapı tipine göre bağlantı uçlarını seçiniz
Kapı kapama butonu
Kapı açma butonu
Fotosel
Kapı sıkışma kontağı
1
2
ÇİZİM
7
ADP
NOT5 19
5
1
ADN
NOT5 20
6
PE
- 100 23C, 1C 37 6, 7 31, 34, 37
10
1000
- 25
8
3
K3
KPS 31
2
12
K5
ACS 33
NOT2
K15
NOT4 6 NOT1
5
30
K16
2A 32
33
8
K19
3A 34
36
K30
1A -
m
S37
k
WITTUR HYDRA PLUS
(-24VDC)
KLEFER VVVF-4
(+24VDC)
1000 : Gösterge ve kontrol devreleri dönüşü (-) ucu
FERMATOR VVVF-4
(+24VDC)
100 : Gösterge ve kontrol devreleri müştereği (+) ucu
FERMATOR 40/10 220VAC
(+24VDC)
K30 : Kapı geri açma sinyal girişi
AKE OSMA
(+24VDC)
K19 : Kapı kapama limit sinyal girişi
AKE ATK V2
D
K16 : Kapı açma limit sinyal girişi
KAT KAPILARI OTOMATİK OLMAYAN VE KABİN KAPISI
KARTLI TELESKOPİK VEYA KATLANIR TİP OLAN
K5 : Kapı açma kontağı dönüşü
K15 : Kapı açma ve kapı kapama kontağı müştereği
E
PRISMA VVVF (JAGUAR)
OTOMATİK KAPI KLEMENS AÇIKLAMALARI
7
PRISMA VVVF (FOX)
5
SIEMENS AT25
4
SIEMENS AT18
3
SEMATIC 2000
2
SELCOM RCRE 24 / RC 48
1
MURAT TEZEL
KONTROL M. SELÇOK
3
TARİH
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
OTOMATİK KAPI BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6/8
LD1
LG2
LD2
LD2
MB
LD1
Kat hizası
n. Durak
5
LG1
4
MB
3
MA
2
MA
1
G
12 cm
MB
3...5 cm
MA
LS2
G
12 cm
MB
MA
LS2
E
C
LD2
Mavi (M1)
Sarı (M0)
Kırmızı (100)
MLA
MLB
B
S-R1
(817)
Min. 16cm
LG1
LS1
LD1
MB
MA
m
LD1
12 cm
E
D
LD2
Kat hizası
1. Durak
MB
3...5 cm
MB
i
12 cm
MA
D
MA
Min. 16cm
12 cm
LG1
LD1
MB
MA
LD2
LD2
LG2
MB
MB
LS1
MA
MA
12 cm
k
LD1
Kat hizası
2. Durak
l
e
F
12 cm
LG2
F
Min. 16cm
Min. 16cm
12 cm
C
.MB
12 cm
S-R2
.MA
(818)
(S-MP)
S-LA
S-LB
(MLA)
(MLB)
B
: Siyah renkli mıknatıs
: Kırmızı renkli mıknatıs
KABİN
: Şerit mıknatıs
: Kontak kapalı
A
LG1,LG2 : Kapı ve kilit açık çalışma alt ve üst bölgesi ( LG1 ve LG2 manuel kat kapılı asansörlerde 20 cm'yi, otomatik kabin kapısıyla birlikte
çalışan otomatik kat kapılı asansörlerde ise 35cm'yi aşmamalıdır. )
LS1
: İnişte yavaşlama yolu
LS2
: Çıkışta yavaşlama yolu
LD1
: Aşağı normal seyahatte ve seviye düzeltmede durma yolu (Aşağıya doğru seviye yenilemenin başlayacağı yukarı kaçma payı) (7 cm)
LD2
: Yukarı normal seyahatte ve seviye düzeltmede durma yolu (Yukarıya doğru seviye yenilemenin başlayacağı aşağı kaçma payı) (7 cm)
NOT1
: Şema, 3 durak içindir. Daha yüksek duraklarda S-R2 'nin kontağı, en üst durağın LS2 başlangıç noktasında açılmalıdır
1
2
3
5
MANYETİK ŞALTER VE ŞERİT MIKNATISLARIN YERLEŞTİRİLMESİ
HİDROLİK ASANSÖRLERDE KULLANIMI
ÇİZİM
4
A
MURAT TEZEL
KONTROL M. SELÇOK
TARİH
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
SAYFA
7/8
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve
eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı
izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
1
E
D
C
2
3
: Aşırı yük sinyal çıkışı
01
031
: Aşağı yön oku sinyal çıkışı
: Yukarı yön oku sinyal çıkışı
032
1
: Kabin ve kabin lambası besleme fazı
2
: Kabin lambası fazı
100
: Gösterge ve kontrol devreleri müştereği (+) ucu
100B
: Batem kartı beslemesi
107
: Hız regülatörü kontağı dönüşü
: Kabin paraşüt fren kontağı dönüşü
108
113
: Patlak hortum kontağı dönüşü
114
: Kabin içi acil stop buton dönüşü
115
: Kabin üstü acil stop buton dönüşü
116
: Kabin gevşek halat kontağı dönüşü
: Kabin çatı kapağı kontağı dönüşü
117
: Yedek
119
: Seri bağlı stop kontakları dönüşü
120
: Kat kapısı kontakları dönüşü
130
: Kabin kapısı kontağı dönüşü
140
291
: Gong sinyal çıkışı
401, ..., 416 : İç kumanda girişleri
: Revizyonda çalışma aşağı yön sinyal girişi
500
501
: Revizyonda çalışma yukarı yön sinyal girişi
: Aşırı yük kontağı dönüşü
804
: Tam yük kontağı dönüşü
805
: Lirpomp bobini (-) ucu
810
: Vatman sinyal girişi
812
: Alt zorunlu yavaşlatıcı kontak dönüşü
817
: Üst zorunlu yavaşlatıcı kontak dönüşü
818
: Revizyona alma anahtarından gelen normal çalışma sinyal girişi
869
: Gösterge ve kontrol devreleri dönüşü (-) ucu
1000
: Lirpomp bobini (+) ucu
2001
m
B
A
1
2
ÇİZİM
MURAT TEZEL
KONTROL M. SELÇOK
(+24VDC)
(+24VDC)
(+24VDC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(220VAC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-180VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-24VDC)
(+180VDC)
i
23.10.2012
ŞEMA NO
1002-R
DOSYA
SX-HD-U-DSB-R-V1
A, B, C, D, E, F, G, -X, 1X, 2X
ADN
ADP
AL1, AL2
CANH, CANL
DTO
DTS
GB0, GB1, GB2, GB3
K3
K5
K15
K16
K19
K30
M0
M1
M2, M3
N1
PE
RB2
TLFA, TLFB, TLFC, TLFD
5
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
6
7
l
e
7 segment gösterge sinyal çıkışı
Otomatik kapı nötrü
Otomatik kapı fazı
Alarm sinyal girişleri
Seri haberleşme sinyalleri
Kapı açma sinyal girişi
Kapı kapama sinyal girişi
Gray kod veya binary kod sinyal çıkışları
Kapı kapama kontağı dönüşü
Kapı açma kontağı dönüşü
Kapı açma ve kapı kapama kontağı müştereği
Kapı açma limit sinyal girişi
Kapı kapama limit sinyal girişi
Kapı geri açma sinyal girişi
Gray kod ve sayıcı (MA) konum bilgisi şalterleri dönüşü
Gray kod ve sayıcı (MB) konum bilgisi şalterleri dönüşü
Gray kod konum bilgisi şalterleri dönüşü
Bağımsız sigortadan geçen kabin nötrü
Topraklama
Revizyon ve Geri Alma anahtarları üzerindeki güvenlik (stop) devresi kontakları dönüşü
Telefon hattı bağlantı girişleri
k
(*) : Kullanılan otomatik kapıya göre değişir
(-24VDC)
(220VAC)
(220VAC)
(+24VDC)
E
(+24VDC)
(+24VDC)
(+24VDC)
(*)
(*)
(*)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(220VAC)
D
(220VAC)
C
B
A
3
TARİH
4
4
HİDROLİK ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
HİDROLİK
REVİZYON KUTUSU
VAR
VAR
< GÜVENLİK DEVRESİ GERİLİMİ
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
8/8
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
YÜZYIL MAH. MATBAACILAR SİTESİ YOLU NO:56 34200 BAĞCILAR / İSTANBUL / TÜRKİYE
TELEFON
+90.212. 629 00 08 pbx
FİRMA
MİK-EL ELEKTRONİK SAN. TİC. LTD. ŞTİ.
KUMANDA SİSTEMİ
MİKRONİK SX
PROJE TANIMI
ASANSÖRLERDE KULLANIMI
ÜNİTE
-
BAĞLANTI
-
KAPI AÇIK SEVİYELEME
-
ERKEN KAPI AÇMA
-
VALF GERİLİMİ
-
GERİ ALMA KUMANDA
-
H/W
-
S/W
-
TARİH
16.12.2010
ŞEMA NUMARASI
1000 - 1 - K
DOSYA İSMİ
SX-KAT-V1
SAYFA SAYISI
7
ÇİZİM
İ.YÖRDENİKLİ
KONTROL
M. SELÇOK
FAKS
+90.212. 629 11 35
WEB
www.mik-el.com
1
2
3
4
5
6
7
l
e
L12-n
DS-n
L02-n
E
n. Durak
L32-n
L-20n
L31-n
S-20n
L12-2
L-302
D
k
S-302
L02-2
2. Durak
L32-2
L-202
L31-2
S-202
i
C
L12-1
L-301
S-301
m
L02-1
1. Durak
L32-1
L31-1
B
12
A
02
L12-1,L12-2,...,L12-n :
L02-1,L02-2,...,L02-n :
L32-1,L32-2,...,L32-n :
L31-1,L31-2,...,L31-n :
032
031
1000
Meşgul lambaları
Servis dışı lambaları
Yukarı yön lambaları
Aşağı yön lambaları
1
100
L-202,...,L-20n :
S-202,...,S-20n :
L-301,...,L-302 :
S-301,S-302
:
NOT1
:
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
NOT1
K-806
301
202
302
20n
NOT3
201
202
YOK
20n
NOT4
Dış kumanda aşağı yön kayıt lambaları
Dış kumanda aşağı yön çağrı butonları
Dış kumanda yukarı yön kayıt lambaları
Dış kumanda aşağı yön çağrı butonları
1KS, 1KSA ve 1KSL için dış kumanda ortağı
3
TARİH
16.12.2010
ŞEMA NO
1000 - 1 - K
DOSYA
SX-KAT-V1
4
ASANSÖRLERDE KULLANIMI
806
E
D
DS-2
C
DS-1
S-816
816
100
B
100
NOT3
NOT4
K-806
S-816
DS-1,DS-2,...,DS-n
a
:
:
:
:
:
b
c
d
e
f
g
-X 1X
1 KS için dış kumanda çağrıları
1KSA, 1KSL, S24 ve S24T için dış kumanda çağrıları
Deprem ihbar kontağı
Yangın ihbar anahtarı
Ortak anod gösterge
5
KAT BUTONYER GÖSTERGELERİ VE DİĞER DIŞ
TESİSAT BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
A
7
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
2/7
1
2
3
4
5
6
L12-n.
7
l
e
DS-n.
L02-n.
E
n. Durak
L32-n.
L-20n.
L31-n.
S-20n.
L12-2.
L-302.
D
k
S-302.
L02-2.
2. Durak
L32-2.
L-202.
L31-2.
S-202.
i
C
L12-1.
L-301.
S-301.
m
L02-1.
1. Durak
L32-1.
L31-1.
B
12
A
L12-1,L12-2,...,L12-n :
L02-1,L02-2,...,L02-n :
L32-1,L32-2,...,L32-n :
L31-1,L31-2,...,L31-n :
02
032
031
Meşgul lambaları
Servis dışı lambaları
Yukarı yön lambaları
Aşağı yön lambaları
1
1000
100
L-202,...,L-20n :
S-202,...,S-20n :
L-301,...,L-302 :
S-301,S-302
:
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
Dış
Dış
Dış
Dış
kumanda
kumanda
kumanda
kumanda
K-806
301
202
302
20n
NOT6
201
202
YOK
20n
NOT7
3
TARİH
16.12.2010
ŞEMA NO
1000 - 1 - K
DOSYA
SX-KAT-V1
4
ASANSÖRLERDE KULLANIMI
D
DS-2.
C
DS-1.
S-816.
806
816
NOT6
NOT7
K-806
S-816
aşağı yön kayıt lambaları
aşağı yön çağrı butonları
yukarı yön kayıt lambaları
aşağı yön çağrı butonları
E
:
:
:
:
100
100
B
a
b
2KS için dış kumanda çağrıları
2KSA için dış kumanda ortağı
Deprem ihbar kontağı
Yangın ihbar anahtarı
5
DUBLEKS SİSTEMLERDE A ASANSÖRÜNÜN KAT
BUTONYER GÖSTERGELERİ VE DİĞER DIŞ TESİSAT
BAĞLANTILARI
c
d
e
f
g
-X 1X
DS-1,DS-2,...,DS-n : Ortak anod gösterge
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
A
7
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
3/7
1
2
3
4
5
6
.L12-n
7
l
e
.DS-n
.L02-n
E
n. Durak
.L32-n
.L31-n
.L12-2
D
.L02-2
.L32-2
2. Durak
i
.L31-2
C
.L12-1
m
.L02-1
1. Durak
.L32-1
.L31-1
B
12
02
032
031
A
1000
L12-1,L12-2,...,L12-n
L02-1,L02-2,...,L02-n
L32-1,L32-2,...,L32-n
L31-1,L31-2,...,L31-n
1
:
:
:
:
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
K-806
806
16.12.2010
ŞEMA NO
1000 - 1 - K
DOSYA
SX-KAT-V1
C
.DS-1
.S-816
816
100
100
B
a
b
c
d
e
f
g
-X 1X
A
3
TARİH
D
.DS-2
K-806
: Deprem ihbar kontağı
S-816
: Yangın ihbar anahtarı
DS-1,DS-2,...,DS-n : Ortak anod gösterge
Meşgul lambaları
Servis dışı lambaları
Yukarı yön lambaları
Aşağı yön lambaları
2
ÇİZİM
k
E
4
ASANSÖRLERDE KULLANIMI
5
DUBLEKS SİSTEMLERDE B ASANSÖRÜNÜN KAT
BUTONYER GÖSTERGELERİ VE DİĞER DIŞ TESİSAT
BAĞLANTILARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
4/7
1
2
3
4
5
KS SİSTEM İÇİN ÇİFT BUTON ÇİFT YÖN TOPLAMALI
E
SX/CPU V1
SV1
SV2 SV3
SV4 SV5 SV6
10 hatlı yassı ters kablo
Gruptaki diğer asansör
sistemine gider
10 hatlı yassı ters kablo
D
SX-BK2
SX-BK1
10
16
i
209
10
C
9
10
10
m
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
307
10
10
10
10
10
10
16.12.2010
ŞEMA NO
1000 - 1 - K
DOSYA
SX-KAT-V1
4
16
303
3
10
10
16
302
202
10
B
5
16
2
SX-DK : Kat gösterge kablosu
SX-BK : Kat çağrı butonları kablosu (Ters Kablo)
1
4
ASANSÖRLERDE KULLANIMI
A
16
301
3
TARİH
6
10
203
C
7
304
204
D
16
305
205
l
e
E
16
306
206
8
7
16
10
207
10
16
308
208
B
k
SX-DK
6
5
HAZIR TESİSATLI UYGULAMALAR İÇİN UYUMLU
KAT BUTONYERİ VE GÖSTERGELERİNE SOKETLİ
BAĞLANTILARI (KS SİSTEM ÇİFT BUTON ÇİFT YÖN
TOPLAMALI İÇİN)
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
5/7
1
2
3
4
5
KSA SİSTEM İÇİN TEK BUTON AŞAĞI YÖN TOPLAMALI,
S24 TOPLAMASIZ SİSTEM
E
SX/CPU V1
SV1
Gruptaki diğer asansör
sistemine gider
10 hatlı yassı ters kablo
D
SX-BK1
SX-BK2
10
i
C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
k
SV2
10 hatlı yassı ters kablo
16.12.2010
ŞEMA NO
1000 - 1 - K
DOSYA
SX-KAT-V1
SV4
SV5
SV6
SX-DK
16
16
10
16
7
l
e
E
D
C
15
10
16
10
10
16
9
10
B
16
8
10
16
7
10
16
A
2
10
16
SX-DK : Kat gösterge kablosu
SX-BK : Kat çağrı butonları kablosu (Ters Kablo)
1
3
TARİH
SV3
6
4
ASANSÖRLERDE KULLANIMI
5
HAZIR TESİSATLI UYGULAMALAR İÇİN UYUMLU
KAT BUTONYERİ VE GÖSTERGELERİNE SOKETLİ
BAĞLANTILAR (KSA VE S24 İÇİN)
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
6/7
1
E
2
3
02
: Servis dışı sinyal çıkışı
12
: Meşgul çıkışı
: Aşağı yön oku sinyal çıkışı
031
032
: Yukarı yön oku sinyal çıkışı
100
: Gösterge ve kontrol devreleri müştereği (+) ucu
201, ..., 216 : Aşağı yön çağrı girişleri
301, ..., 316 : Yukarı yön çağrı girişleri
401, ..., 416 : İç kumanda girişleri
: Deprem kontağı dönüşü
806
: Yangın sinyal girişi
816
: Gösterge ve kontrol devreleri dönüşü (-) ucu
1000
4
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(+24VDC)
(-24VDC)
D
i
C
m
B
A
1
2
ÇİZİM
İ.YÖRDENİKLİ
KONTROL M. SELÇOK
16.12.2010
ŞEMA NO
1000 - 1 - K
DOSYA
SX-KAT-V1
6
7
l
e
A, B, C, D, E, F, G, -X, 1X, 2X : 7 segment gösterge sinyal çıkışı
GB0, GB1, GB2, GB3, GB4, GB5 : Gray kod veya binary kod sinyal çıkışları
M0, M1, M2, M3
: Gray kod konum bilgisi şalterleri dönüşü
k
(-24VDC)
(+24VDC)
(+24VDC)
E
D
C
B
A
3
TARİH
5
4
ASANSÖRLERDE KULLANIMI
5
KLEMENS İSİMLERİ VE AÇIKLAMALARI
6
ÜNİTE
BAĞLANTI
KAPI AÇIK SEVİYELEME
ERKEN KAPI AÇMA
VALF GERİLİMİ
GERİ ALMA KUMANDA
7
-
Bu belge, uygulamalar için öneri niteliğindedir. Mik-el Elektronik San. Tic. Ltd. Şti. önceden haber vermeksizin belgenin içerik veya görünümünde değişiklik yapma hakkını saklı tutar. Belgede yeralabilecek olası hata ve eksikliklerden Mik-el Elektronik San. Tic. Ltd. Şti. sorumlu tutulamaz.
© Bu belge Mik-el Elektronik San. Tic. Ltd. Şti. 'nin malıdır. Her türlü kullanım hakkı Mik-el Elektronik San. Tic. Ltd. Şti. 'ne aittir ve telif hakları yasasınca koruma altındadır. Mik-el Elektronik San. Tic. Ltd. Şti. 'nin yazılı izni olmadan hiçbir şekilde çoğaltılamaz ve üzerinde değişiklik yapılamaz.
SAYFA
7/7
M ik r o n ik S X H id r o lik 2 K S A -1 2
1
2
0 3 2
3 1
1 2
0 2
1 0 0
3 C
4 A
4 C
V 1
6 A
6 C
7 K
2 2 0 V
C
1 2 0
E N T
J 1
N
B
0 3 2
3 1
1 2
0 2
1 0 0
G B 3
G B 2
G B 1
G B 0
1 0 0 0
V 1
5
1 3 0
E S C
1 4 0
D O W N
U P
E N T
V
J 1
2
20
1
20
2
20
3
20
4
20
5
20
6
20
7
20
8
20
9
21
0
21
1
21
2
2 0 2
2 0 3
2 0 4
2 0 5
2 0 6
2 0 7
2 0 8
2 0 9
2 1 0
2 1 1
2 1 2
1
0 0
0 0
S V 2
2
K S A
2 0 1
V
5
6
X 2
1 4 2
8 1 7
8 1 8
1 0 0 0
C A N L
C A N H
1 0 0 0 0
1 0 0
1 0 0
P 2
S
S
1 0 B
P 1
F
B
A
1 0 0
1 2 0
6
E
C
1 0 A
V
8 0 6
8 1 6
1 0 0
6
2
D
1
0
9
8
7
6
5
4
3
2
A
1
2 2 0 V
S V 1
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0 0
0 0
0
7 C
S V 4
P 1
1 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
2 1
2 1
2 1
2 1
A
1 X
-X
G
0
1
0
2
0
7 K
1 0
1 0 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
1 4 2
8 1 7
8 1 8
1 0 0 0
C A N L
C A N H
1 0 0 0 0
1 0 0
1 0 0
S V 3
K S A
C
1
S X /C P U
X 1
K S A
9
C
0
5 C
X 2
S V 2
9
0
5 A
S
V
S V 1
1
0
5 K
S
1 0 B
X 1
1
T
U
4 C
1 0 0
1 4 0
O
T
U
4 A
A
1 0 A
U P
O
2
N
3 C
F
E
D
D O W N
I
1
N
6 C
7 C
E S C
I
B
L
6 A
1 X
-X
G
1 3 0
M
A
L
3 A
G B 3
G B 2
G B 1
G B 0
1 0 0 0
5 C
N
M
U
R
S V 3
S V 4
P 1
1 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
2 1
2 1
2 1
2 1
5 A
K
0
7
0
S X /C P U
5 K
8
9
6
P 2
0
8
1
0
0
3 A
2
5
0
0
1 2 C
1
1
5
2 A
P 1
C
6
C
8 0 6
8 1 6
1 0 0
0
5
0
4
T
3
T
2
2
1
1
0
B
2
A
9
U
1
0
8
9
0
1
7
0
A
1 0
1 0 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
1 2 C
A
9
9
0
6
9
0
8
1
U
5
1
U
7
O
N
4
O
N
6
I
L
3
I
L
5
M
R
2
M
7
4
K
6
P A N O S U B
21
6
8
0
3
8
0
21
5
5
1 A
5
2 A
K U M A N D A
21
4
1 A
P A N O S U A
21
3
K U M A N D A
M ik r o n ik S X H id r o lik 2 K S -7
1
2
0 3 2
3 1
1 2
0 2
1 0 0
3 C
4 A
4 C
V 1
6 A
6 C
7 K
2 2 0 V
C
1 2 0
E N T
J 1
N
B
1 3 0
5
E S C
1 4 0
D O W N
E N T
V
7
20
1
20
2
20
3
20
4
20
5
20
6
20
7
20
8
20
9
21
0
21
1
21
2
3 0 2
3 0 3
3 0 4
3 0 5
3 0 6
2 0 2
2 0 3
2 0 4
2 0 5
2 0 6
2 0 7
1
0 0
0 0
S V 2
2
K S
3 0 1
V
5
6
X 2
1 4 2
8 1 7
8 1 8
1 0 0 0
C A N L
C A N H
1 0 0 0 0
1 0 0
1 0 0
P 2
F
S
S
J 1
P 1
6
U P
1 0 B
6
E
B
A
1 0 0
1 2 0
V
8 0 6
8 1 6
1 0 0
G B 3
G B 2
G B 1
G B 0
1 0 0 0
V 1
C
6
5
4
3
0 3 2
3 1
1 2
0 2
1 0 0
1 0 A
6
2
2
D
5
4
3
2
A
1
2 2 0 V
S V 1
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0 0
0 0
0
7 C
S V 4
P 1
1 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
2 1
2 1
2 1
2 1
A
1 X
-X
G
0
0
1
2
0
7 K
1 0
1 0 0
3 0
3 0
3 0
3 0
3 0
3 0
2 0
2 0
2 0
2 0
2 0
2 0
1 4 2
8 1 7
8 1 8
1 0 0 0
C A N L
C A N H
1 0 0 0 0
1 0 0
1 0 0
S V 3
K S
C
1
S X /C P U
X 1
K S
9
C
0
5 C
X 2
S V 2
9
0
5 A
S
V
S V 1
1
0
5 K
S
1 0 B
X 1
1
T
U
4 C
1 0 0
1 4 0
O
T
U
4 A
A
1 0 A
U P
O
2
N
3 C
F
E
D
D O W N
I
1
N
6 C
7 C
E S C
I
B
L
6 A
1 X
-X
G
1 3 0
M
A
L
3 A
G B 3
G B 2
G B 1
G B 0
1 0 0 0
5 C
N
M
U
R
S V 3
S V 4
P 1
1 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
2 1
2 1
2 1
2 1
5 A
K
0
7
0
S X /C P U
5 K
8
9
6
P 2
0
8
1
0
0
3 A
2
5
0
0
1 2 C
1
1
5
2 A
P 1
C
6
C
8 0 6
8 1 6
1 0 0
0
5
0
4
T
3
T
2
2
1
1
0
B
7
A
9
U
6
0
8
9
5
1
7
0
A
1 0
1 0 0
3 0
3 0
3 0
3 0
3 0
3 0
2 0
2 0
2 0
2 0
2 0
2 0
1 2 C
A
4
9
0
6
9
0
3
1
U
5
1
U
2
O
N
4
O
N
6
I
L
3
I
L
5
M
R
2
M
7
4
K
6
P A N O S U B
21
6
8
0
3
8
0
21
5
5
1 A
5
2 A
K U M A N D A
21
4
1 A
P A N O S U A
21
3
K U M A N D A
B L O K D ÝY A G R A M I
K U M A N D A P A N O S U
1 A
5
5
8
8
K
M
M
I
I
O
O
1
1
9
9
0
1
9
0
U
A
B
1
2
T
T
0
0
C
C
2 A
0
1 2 C
0
6
7
R
L
L
N
N
U
U
1
3 A
0
2
0
A
0
A
1
2
0 3
3
1
0
3 C
4 A
2
S X /C P U
5 K
5 A
V 1
6 A
1 X
-X
G
6 C
7 K
7 C
B
A
1 0 0
1 3 0
E S C
1 4 0
D O W N
U P
E N T
S
S
V
1 0 B
J 1
V
5
R E V IZ Y O N K U T U S U
S V 2 2
D
C
A
B
2
1
G B 3
J 4
G B 2
J 3
1 0 0
K 1 6
K 1 9
K 3 0
K 3
K 5
K 1 5
1 0 0
8 0 4
8 0 5
IN 1
O U T 1
J 2
G B 0
J 1
S X /C A B V 1
G B 1
1 0 0
1 0 0
1 0 0 0
2 9 1
2
1
0
1 0
M
M
M
M
8
7
2
0
3
S V 2 1
X 1
S V 2 1
0
1
2
S V 2 2
6
1 0 0 0
0 1
5
4
3
2
1
S X /T R M
V 1 G
9
8
7
6
5
4
3
1
2
0
0 0
1 0 0 0
0 3 2
0 3 1
1 0 0
1 0 0 0
B 0 /A
G B 1 /B
G B 2 /C
G B 3 /D
E
F
G
-X
1 X
1 0 0
D T O
D T S
0
1 0 0
8 1 2
A Þ IR I Y Ü K
4 1
4 1
4 1
4 1
4 1
4 1
4 1
4 0
4 0
4 0
4 0
4 0
4 0
4 0
4 0
4 0
1 0
1 0
P 2
P 1
6
5
4
3
2
1
0
2 0 2
2 0 3
9
8
7
6
5
4
3
2
3 0 1
3 0 2
1
0 0
0 0
S V 4
P 1
1 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 0
2 1
2 1
2 1
2 1
2 1
2 1
2 1
S V 3
2
7
8
0 0
N L
N H
0 0 0
0
0
S V 2
1 4
8 1
8 1
1 0
C A
C A
1 0
1 0
1 0
S V 1
0
6
X 2
8 0 6
8 1 6
1 0 0
X 1
0
F
C
1 2 0
1 0
1 4
8 1
8 1
1 0
E
D
2 2 0 V
1 0 A
2
7
8
0 0
C A N L
C A N H
1 0 0 0
1 0 0
1 0 0
2
G B 3
G B 2
G B 1
G B 0
1 0 0 0
5 C
N
1
2
1 0 0
4 C
1 4
8 1
8 1
1 0
S ÝS T E M ÝN
Download